Ras-07Ukp-Es3 / Ras-07Ua-Es3 - Toshiba RAS-13UKHP-ES3 Service Manual

Hide thumbs Also See for RAS-13UKHP-ES3:
Table of Contents

Advertisement

5-5. RAS-07UKP-ES3 / RAS-07UA-ES3

Cooling
0.39m
(Connecting pipe)
∅9.52
O.D.:9.52mm
Packed valve
Cooling
Cooling Compressor
Cooling
50Hz
Standard
Cooling
Overload
Low temperature
Note :
• Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
P
(∅9.52)
PA79X1T-4FZ5
Condenser
Propeller fan
Outdoor unit
Standard
pressure P
(MPaG)
0.97
1.13
0.63
T1
Indoor unit
Evaporator
Cross flow fan
Mark(
Surface temp. of heat
exchanger interchanging
pipe T1 (°C)
14.0
20.0
2.0
− 21 −
FILE NO. SVM-04001
Packed valve
(∅6.35)
Capillary tube
∅1.2x650l
Refrigerant
R-22 : 0.65 kg.
)means check points of Gas Leak.
conditions DB/WB
Fan speed
(indoor)
Indoor
High
27/19
High
32/23
Low
21/15
0.49m
(Connecting pipe)
∅6.35
O.D.:6.35mm
Ambient temp.
(°C)
Outdoor
35/24
43/26
21/15