4-3. Outdoor Unit (RAS-13UA-ES3, RAS-13UA-AS3)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)

4-4. Outdoor Unit (RAS-10UAH-ES3, RAS-10UAH-AS3)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
Solenoid coil
5
(for 4-way valve)
Type
Output (Rated) 1100W , 2poles, 1 phase, 220 − 240V, 50Hz
PA150X2T-4FM1 Winding resistance (Ωı )
(at 20°C)
Output (Rated) 30W, 6poles, 1 phase, 220 − 240V, 50Hz
HF-240-30B
Winding resistance (Ωı )
(at 20°C)
DS451155BPQC AC 450V, 1.5µˇ F
DS371306CPNB
AC 370V, 30µˇ F
Type
Output (Rated) 750W , 2poles, 1 phase, 220 − 240V, 50Hz
PA108X1T-4FZ1
Winding resistance (Ωı )
(at 20°C)
Output (Rated) 30W, 6poles, 1 phase, 220 − 240V, 50Hz
HF-240-30B
Winding resistance (Ωı )
(at 20°C)
DS451155BPQC AC 450V, 1.5µˇ F
DS371256CPNB
AC 370V, 25µˇ F
AC 220 − 240V
SQ-373
− 14 −
FILE NO. SVM-04001
Specifications
C-R
2.49
Red-Black
245
Specifications
C-R
3.89
Red-Black
245
C-S
3.95
White-Black
388.3
C-S
4.51
White-Black
388.3