4.6
Receiver Section
Item
Condition
1. Receive
1) Test CH : Low, Low', Center,
Sensitivity
High', High ( 5 point )
[Semiauto-
2) SSG output : -90dBm
matic]
AF Freq : 1kHz
Mod Dev : ±1.5kHz
2. Open
[Analog Narrow]
Squelch (5)
1) Test CH : Low, Low', Center,
High', High ( 5 point )
2) SSG output : -120dBm
AF Freq : 1kHz
Mod Dev : ±1.5kHz
[Analog Wide]
1) Test CH : Low, Low', Center,
High', High ( 5 point )
2) SSG output : -120dBm
AF Freq : 1kHz
Mod Dev : ±3.0kHz
[NXDN Very Narrow]
1) Test CH : Low, Low', Center,
High', High ( 5 point )
2) SSG output : -124dBm
AF Freq : 400Hz
Mod Dev : ±1.1kHz
[NXDN Narrow]
1) Test CH : Low, Low', Center,
High', High ( 5 point )
2) SSG output : -122dBm
AF Freq : 400Hz
Mod Dev : ±2.2kHz
3. Tight
[Analog Narrow]
Squelch
1) Test CH : Low, Low', Center,
High', High ( 5 point )
2) SSG output : -116dBm
AF Freq : 1kHz
Mod Dev : ±1.5kHz
[Analog Wide]
1) Test CH : Low, Low', Center,
High', High ( 5 point )
2) SSG output : -116dBm
AF Freq : 1kHz
Mod Dev : ±3.0kHz
1-28 (No.RA028<Rev.001>)
Measurement
Test-
Unit
Terminal
equipment
SSG
ANT
Oscilloscope
Audio
Analyzer
SSG
ANT
Oscilloscope
Audio
Analyzer
SSG
ANT
Oscilloscope
Audio
Analyzer
SSG
ANT
Oscilloscope
Audio
Analyzer
SSG
ANT
Oscilloscope
Audio
Analyzer
SSG
ANT
Oscilloscope
Audio
Analyzer
SSG
ANT
Oscilloscope
Audio
Analyzer
Adjustment
Unit
Parts
Method
FPU Press [Start], [Auto
tuning]
FPU Press [Start], [Auto
tuning]
FPU Press [Start], [Auto
tuning]
FPU Press [Start], [Auto
tuning]
FPU Press [Start], [Auto
tuning]
FPU Press [Start], [Auto
tuning]
FPU Press [Start], [Auto
tuning]
Specifica-
tions
/Remarks