SECURING HEATER TO FLOOR OR HEARTH
Note: Clearance requirements as detailed in "CLEARANCES and HEIGHT REQUIREMENTS" section on
page 17 of this manual, must be met before securing the heater in place.
To prevent movement, the heater must be secured to the floor or hearth.
1. Open the control access door and remove the screen.
2. Remove carton containing the four-log set.
3. To remove the grate and base assembly, take out two (2) screws as shown in Figure 16.
4. Lift grate and base assembly out of the firebox.
5. Secure the firebox with two anchoring screws (
Note: If the unit is mounted on carpeting, tile or combustible material without the hearth, a metal or wooden
base covering the entire width and depth of the base must be installed.
Screws
Grate
Figure 16 - Removing Grate
33D4047
GENERAL INSTALLATION INFORMATION
/
" x 1
/
" length) supplied with the fireplace system. See Figure 17.
3
1
16
4
3/16" x 1 1/4"
Anchor Screws
Figure 17 - Securing Heater to Floor or
Hearth