8. Always switch off at the mains before disconnecting
any plug, cable connector or extension cable.
9. Never pull on the cable to disconnect any of the plugs.
10.Switch off, remove plug from mains and examine electric
supply cable for damage or ageing before winding cable
for storage. Do not repair a damaged cable, replace it
with a new one. Use only Flymo replacement cable.
11.Always wind cable carefully, avoiding kinking.
12.Use only on AC mains supply voltage shown on
the product rating label.
13.Flymo trimmers are double insulated to EN60335.
Under no circumstance should an earth be con-
nected to any part of the trimmer.
Preparation
1. While using your product always wear substantial
footwear and long trousers.
2. Before using the machine and after any impact,
check for signs of wear or damage and repair as
necessary.
3. Inspect the area to be cut before each use. Remove
all objects such as stones, broken glass, nails, wire,
string etc, which can be thrown or become entangled
in the trimmer head.
4 . Check that the cutting head is fitted correctly.
Use
1. Use the product only in daylight or good artificial light.
2. Avoid operating your product in wet grass, where
feasible.
3. Take care in wet grass, you may lose your footing.
4. On slopes, be extra careful of your footing and
wear non-slip footwear.
5. Do not walk backwards when operating, you could
trip. Walk never run.
6. Keep cutting head below waist level.
7. Never operate the product with damaged guards
or without guards in place.
8. Never fit metal cutting elements.
IMPORTANT
Use only 1.00mm
2
size cable up to 40 metres length
maximum.
Maximum rating:
1.00mm
2
size cable, 10 amps 250 volts AC.
YOUR PRODUCT IS SUPPLIED WITH AN
ELECTRIC MAINS CABLE WIRED DIRECTLY
INTO THE PRODUCT.
1. Flymo Mains Cables and Extension Cables are
available from your local Approved Service Centre.
2. Do not wire an extension cable directly to your product
yourself. Please contact your local Approved Service
Centre for further information on the connectors and
kits available.
3. Only use extension cables specifically designed for
outdoor use.
CONNECTORS
Flymo connectors are suitable for use with 2 core cable
only. Under no circumstances should these connectors
be used for earthed products. All Flymo connectors and
cables are of splashproof construction. They are not
waterproof and must not be left outside permanently nor
should they be submerged or immersed in water. Do
not let cable lay or trail through pools of water or
splashed with water from hose pipes.
MAINS PLUG REPLACEMENT
If the plug supplied is cut off it should be destroyed.
There is an electric shock hazard if a cut off plug is
inserted into a 13 amp socket.
9. Keep hands and feet away from the cutting means at
all times and especially when switching on the motor.
10.Never pick up or carry a product by the cable.
11.Do not lean over the trimmer guard - objects may
be thrown by the cutting line.
12.Beware of cut-off pieces of nylon line ejected during use.
13.Remove the plug from the mains :
-
before leaving the product unattended for any period;
-
before clearing a blockage;
-
before checking, cleaning or working on the appliance;
-
if you hit an object. Do not use your product until you
are sure that the entire product is in a safe operating
condition;
-
if the product starts to vibrate abnormally. Check im-
mediately. Excessive vibration can cause injury.
Maintenance and storage
1. Keep all nuts, bolts and screws tight to be sure the
product is in safe working condition.
2. Replace worn or damaged parts for safety.
3. Only use the replacement cutting line specified for
this product.
4. Only use replacement parts and accessories
recommended by Husqvarna UK Ltd.
5. To avoid the risk of injury keep fingers and hands
clear of the line cutter on the leading edge of the
guard.
6. Clean unit with a dry cloth. Never use metal objects to
clean the unit.
7. Inspect and maintain the product regularly. Any
repairs must be carried out by an authorised
repairer.
8. Store in a cool dry place and out of reach of
children. Do not store outdoors.
Cables
1. No earth required. Flymo products are double
insulated to EN60335 and under no circumstances
should an earth be connected to any part of the
product.
2. Ensure the mains voltage suits your product.
3. IMPORTANT!
The wires in the mains lead are coloured in accordance
with the following code:
BLUE
-
BROWN
-
The wire which is coloured BLUE must be connected to
the Terminal which is marked with the letter ʻNʼ or
coloured BLACK. The wire which is coloured BROWN
must be connected to the Terminal which is marked with
the letter ʻLʼ or coloured RED.
4. It is important that the outer sheath is clamped
correctly into the 3-pin plug.
5. If in doubt consult your local Service Repairer or
qualified electrician before the machine is used.
6. A 13 Amp fuse must be fitted to the Mains Plug.
7. The normal plug fuse and household fuse only
protect the electrical equipment and are not a
safeguard against electrocution.
If your product is hard wired i.e. non-detachable
mains electric cable, a conversion kit and
extension cable is available from all Approved
Service Centres which can be found in your local
Yellow Pages.
NEUTRAL