PRODUCT FEATURES
PRODUCT SPECIFICATIONS
•
This appliance has been certified for use with either
natural or propane gas. See appropriate data plates.
•
This appliance is not for use with solid fuels.
•
The appliance must be installed in accordance with
local codes if any. If none exist use the current instal-
lation code, ANSI Z223.1/NFPA 54 in the US and
CSA B149 in Canada.
•
The appliance must be properly connected to a vent-
ing system.
•
The appliance is not approved for closet or recessed
installations.
FP1920
Gas Control
(not shown)
Figure 1 -
BBV/SBV Fireplace
HIGH ELEVATIONS
FP1920
BBV SBV parts
Input ratings are shown in BTU per hour and are cer-
9/08
tified without deration for elevations up to 4,500 feet
(1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA, in-
stallation must be in accordance with the current ANSI
Z223.1/NFPA 54 and/or local codes having jurisdic-
tion.
In Canada, please consult provincial and/or local au-
thorities having jurisdiciton for installation at elevations
above 4,500 feet (1,370 m).
62D4036
BBV, SBV Series Natural Vent Gas Fireplaces
GAS PRESSURES
Inlet Minimum
Inlet Maximum
Manifold Pressure
GAS SPECIFICATIONS & ORIFICE SIZE
Model
BBV400NV
BBV400PV
SBV400NV
SBV400PV
SBV500NV
SBV500PV
BEFORE YOU START
1/2"
Nailing
Read this homeowner manual thoroughly and follow all
Flange
instructions carefully. Inspect all contents for shipping
damage and immediately inform your dealer if any dam-
age is found. Do not install any unit with damaged, incom-
5/8"
plete, or substitute parts. Check your packing list to verify
Nailing
Flanges
that all listed parts have been received. You should have
the following:
•
Fireplace (Firebox and Burner System)
•
Log Set
•
Rock Wool
•
Switch Cover Plate
1/2"
Nailing
•
Ziplock Bag 2" x 3" x 3"
Flange
ITEMS REQUIRED FOR INSTALLATION
•
Phillips Screwdriver
•
Hammer
•
Saw and/or saber saw
•
Electric Drill and Bits
•
Pliers
•
Square
•
Caulking Material (Noncombustible)
•
Fireplace Surround Material (Noncombustible)
•
Piping Complying with Local Codes
•
Pipe Sealant Approved for use with Propane/LPG
(Resistant to Sulfur Compounds)
Natural
4.5" w.c.
10.5" w.c.
3.5" w.c.
Max.Input
Min. Input
Fuel
BTU/h
BTU/h
Nat.
22,000
16,000
LP
22,000
14,500
Nat.
29,000
16,500
LP
29,000
16,300
Nat.
31,500
19,000
LP
31,500
20,000
•
Volcanic Rock
•
White Toggle Switch
•
Plastic Bag (1)
•
Framing Materials
•
Wall Finishing Materials
•
Level
•
Tee Joint
•
Measuring Tape
•
Pipe Wrench
Propane (LP)
11.0" w.c.
13.0" w.c.
10.0" w.c.
Orifice
Size
#43
#55
#41
#53
#37
#52
5