Indoor Unit (Ras-18,24Nkpx-T) - Toshiba RAS-24NKHP-E Service Manual

Table of Contents

Advertisement

4-3. Indoor Unit (RAS-18,24NKPX-T)

No.
Parts name
1
Fan motor (for indoor)
2
Thermo sensor (TA-sensor)
3
Switching transformer (T01)
4
Microcontroller
5
Heat exchanger sensor
(TC-sensor)
6
Line filter (L01)
7
Diode (DB01)
8
Capacitor (C02)
9
Fuse (F01)
10
Relay (for outdoor fan motor,
solenoid coil) (RY04)
11
Switching IC (IC01)
12
Varistor (R21, R22)
13
Resistor (R01)
14
Louver motor
4-4. Indoor Unit (RAS-18N2AX-T)
No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5
Magnetic contactor
Type
ICF-340-30-2
———
SWT-58A
TMP87CM40ANG
———
SS11V-R07190
D3SBA60
KMH450VNSN120M25S
TSCR
AJQ1341
MA8920
15G561K
RF-5TK4R7
MP35EA12
Type
Output (Rated) 1500 W, 2 poles, 1 phase, 220 – 240 V, 50 Hz
PH290X2C-4FT1
Winding resistance (Ω)
(at 20°C)
Output (Rated) 42 W, 4 poles, 1 phase, 220 – 240 V, 50 Hz
FG-240-42A
Winding resistance (Ω)
(at 20°C)
451305L
AC 450 V, 3.0µF
RA44B356U0215S AC 440 V, 35µF
CLK-26J
220 – 240 V, 50 Hz
− 12 −
FILE NO. SVM-06009
Specifications
DC 340 V, 30 W
10 kΩ at 25°C
DC 390 V, Secondary DC 15 V, 12 V, 7 V
6G60
10 kΩ at 25°C
19 mH, AC 0.7 A
4 A, 600 V
120µF, 450 V
T6.3 A, 250 V
Coil DC 12 V, 33 mA, Rated contact1 A, AC 250 V
5 A, 900 V
560 V
4.7 Ω, 5 W
Output (Rated) 2 W, 10 poles, 1 phase,
DC 12 V
Specifications
C-R
1.71
Red-Black
128
C-S
3.09
White-Black
126

Hide quick links:

Advertisement

Table of Contents
loading