B. Design and Installation Considerations
NOTICE: Check building codes prior to installation.
Installation MUST comply with local, regional, state and
national codes and regulations.
Consult insurance carrier, local building inspector, fire
officials or authorities having jurisdiction over restrictions,
installation inspection and permits.
Before installing, determine the following:
-
Where the fireplace is to be installed.
-
The vent system configuration to be used.
-
Gas supply piping.
-
Electrical wiring.
-
Framing and finishing details.
-
Whether optional accessories - devices such as a
fan, wall switch or remote control - are desired.

1. Selecting Fireplace Locations

This fireplace may be used as a room divider, installed
along a wall, across a corner or used in an exterior chase.
See Figure 2.2.
Locating the fireplace in a basement is not recommended.
Locating near frequently opened doors, central heat
outlets or returns, or other locations of considerable air
movement can affect the performance.
E
D
As a
room
divider
(2134 mm)
(1219 mm)
Model #
BIR42
Figure 2.2
Fireplace Locations
6
Heatilator • Birmingham 42-B Installation Manual • 4059-715 • Rev P • 09/28/15
F
Across a
B
C
corner
G
B
84 in.
48 in.
MINIMUM
A
in.
77 7/8
mm
1978
Consideration should be given to these factors before
deciding on a location.
NOTICE: In addition to these framing dimensions, also
reference the following section:
• Clearances (Section 3).
NOTICE:
• Illustrations and photos reflect typical installations and
are FOR DESIGN PURPOSES ONLY.
• Illustrations/diagrams are not drawn to scale.
• Actual installation/appearance may vary due to individual
design preference.
• Hearth & Home Technologies reserves the right to alter
its products.
NOTICE:
A minimum 1-1/2 in. air clearance at the back and
a minimum 1-1/2 in. air clearance to the sides of
the fireplace assembly must be maintained.
Chimney sections at any level require a 2 in. mini-
mum air space clearance between the framing
and chimney sections.
B
A*
In an exterior chase
or projecting into a
garage
24 in. (610 mm)
from fireplace opening to
any perpendicular wall
Along a wall
A
B
B
C
D
53 7/8
95 1/4
47 5/8
1368
2419
1210
Note:
1-1/2 in. min. air space
from fireplace to
G
combustible materials.
1/2 in. min. air space at
nailing flanges.
* 12 in. (305 mm) extra space
included for each outside air
connection. If outside air
duct hnas no bend, this
cimension may be reduced
as long as minimum clear-
ances are met.
1/2 in. (13 mm) all
configurations
G
E
F
G
22 1/2
67 3/8
28 1/2
572
1711
724