Heatilator ECO-ADV-WS22 Owner's Manual
Heatilator ECO-ADV-WS22 Owner's Manual

Heatilator ECO-ADV-WS22 Owner's Manual

Heatilator eco-adv-ws22 wood burning stove
Hide thumbs Also See for ECO-ADV-WS22:
Table of Contents

Advertisement

Model:
ECO-ADV-WS22
Wood Burning Stove
If the information in these instruc-
tions is not followed exactly, a
fi re may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• Do not overfi re - If heater or chimney con-
nector glows, you are overfi ring. Overfi ring
will void your warranty.
• Comply with all minimum clearances to
combustibles as specifi ed. Failure to
comply may cause house fi re.
WARNING
Fire Risk.
For use with solid wood fuel only.
Other fuels may overfi re and generate
poisonous gases (i.e. carbon monoxide).
www.heatilator.com
Consumer Care 1-877-427-3316 - Prior to calling, please have the model and serial number of the unit you are calling
about. This information can be found at the front of the unit.
DO NOT DISCARD THIS MANUAL
• Read, understand and
Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING
7057-128G • May 4, 2015
WS22
NOTICE
follow these instructions
for safe installation and
operation.
Hot glass will cause burns.
Do not touch glass until it is cooled
NEVER allow children to touch glass
Keep children away
CAREFULLY SUPERVISE children in same room as
fi replace.
Alert children and adults to hazards of high
temperatures.
High temperatures may ignite clothing or other
fl ammable materials.
Keep clothing, furniture, draperies and other fl ammable
materials away.
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for
use and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are
hot during operation AND
cool down.
Installation and service of this appliance should
be performed by qualifi ed personnel. Hearth &
Home Technologies recommends NFI certifi ed
professionals, or technicians supervised by an
NFI certifi ed professional.
1

Advertisement

Table of Contents
loading

Summary of Contents for Heatilator ECO-ADV-WS22

  • Page 1 Owner’s Manual Installation and Operation Model: ECO-ADV-WS22 Wood Burning Stove WS22 NOTICE DO NOT DISCARD THIS MANUAL • Read, understand and • • Leave this manual with Important operating follow these instructions party responsible for a n d m a i n t e n a n c e for safe installation and use and operation.
  • Page 2: Congratulations

    Read this manual before installing or operating this fi replace. Please retain this owner’s manual for future reference. Congratulations! Congratulations on selecting a Heatilator wood burning This owner’s manual should be retained for future refer- appliance. The wood burning appliance you have selected ence.
  • Page 3: Table Of Contents

    ECO-ADV-WS22 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided may result in death or serious injury. • CAUTION! Indicates a hazardous situation which, if not avoided, may result in minor or moderate injury.
  • Page 4: Warranty Policy

    HEATILATOR ECO-CHOICE WARRANTY Hearth & Home Technologies Inc., on behalf of its hearth brands (“HHT”), extends the following warranty for ECO- CHOICE by heatilator wood and pellet hearth appliances that are purchased from an HHT authorized dealer. WARRANTY COVERAGE: HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking owner- ship of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance will be free from defects in materials and workmanship at the time of manufacture.
  • Page 5 ECO-ADV-WS22 WARRANTY COVERAGE: • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of HHT authorized dealers is available on the HHT branded websites. • This warranty is only valid while the HHT appliance remains at the site of original installation.
  • Page 6: Section 1: Listing And Code Approvals

    NOTE: Hearth & Home Technologies, manufacturer of this appliance, reserves the right to alter its products, their specifi cations and/or price without notice. Heatilator is a registered trademark of Hearth & Home Technologies. 7057-128G • May 4, 2015...
  • Page 7: Section 2: Operating Instructions

    ECO-ADV-WS22 User Guide Operating Instructions WARNING HOT SURFACES! Glass and other surfaces are hot during operation AND cool down. Hot glass will cause burns. • DO NOT touch glass until it is cooled • NEVER allow children to touch glass •...
  • Page 8: Fire Safety

    ECO-ADV-WS22 B. Fire Safety Hearth & Home Technologies WILL NOT warranty stoves that exhibit evidence of over-fi ring. Evidence of over-fi ring To provide reasonable fi re safety, the following should be given includes, but is not limited to: serious consideration: •...
  • Page 9: Burning Process

    ECO-ADV-WS22 F. Chimney Fire If heat is robbed from the appliance during the drying stage, the new load of wood has reduced the chances for a good WARNING! Risk of Fire! A chimney fi re can permanently clean burn. damage your chimney system and nearby structures.
  • Page 10: Burn Rate Air Control

    ECO-ADV-WS22 H. Burn Rate Air Control I. Burn Rates and Operating Effi ciency • The air supply enters at the upper front of the fi rebox, For maximum operating effi ciency near the top of the glass door. 1. Follow the instructions below for each burn rate for the •...
  • Page 11: Correct Baffl E & Blanket Placement

    ECO-ADV-WS22 INCORRECT POSITIONS J. Correct Baffl e & Blanket Placement WARNING! Risk of Fire! Firebox damage due to improper baffl e placement is not covered by warranty. Operate the wood burning appliance with the baffl e in the correct position only.
  • Page 12: Building A Fire

    ECO-ADV-WS22 K. Building A Fire 9. When ready to reload, It is best to set the Burn Rate Air Control in the High position before reloading. WARNING! Risk of Fire! Keep combustible materials, • This livens up the coalbed and reduces excessive emis- gasoline and other fl...
  • Page 13: Wood Fuel

    ECO-ADV-WS22 L. Wood Fuel Moisture WARNING! Risk of Fire! WARNING • Do NOT burn wet or green wood. • Wet, unseasoned wood can cause accumulation of Fire Risk. creosote. • DO NOT BURN GARBAGE OR FLAMMABLE • Store wood in dry location.
  • Page 14: Blower Operating Instructions

    ECO-ADV-WS22 M. Blower Operating Instructions NOTE: If your wood appliance is equipped with an optional blower, you should follow these guidelines: Blower Burn Rate Air Control Handle Up = Open Handle Down = Closed Snap Disc Figure 14.2 - Snap Disc Location Snap Disc Location If you fi...
  • Page 15: Opacity (Smoke)

    ECO-ADV-WS22 O. Opacity (Smoke) CAUTION! Odors and vapors released during initial Opacity is the measure of how cleanly your appliance is operation may be irritating to sensitive individuals. burning. Open windows for air circulation. Opacity is measured in percent: •...
  • Page 16: Quick Start Guide

    ECO-ADV-WS22 Q. Quick Start Guide 10 Pieces of Newspaper, 10-20 Pieces of Dry Kindling FIRST FIRE ITEMS NEEDED: and a Few Pieces of Dry Split Wood. OPEN AIR ADD NEWSPAPER LOAD WOOD CONTROL HIGH ADD KINDLING WARNING! Risk of Fire Close and securely latch the door after the fi...
  • Page 17: Section 3: Maintenance And Service

    ECO-ADV-WS22 Maintenance and Service Creosote - Formation and Need for Removal A. Disposal of Ashes • When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to • Frequency: When ash is within 1-3/4 inch (44mm) of form creosote.
  • Page 18: Glass Cleaning

    ECO-ADV-WS22 E. Firebrick Inspection D. Glass Cleaning • Frequency: After each ash removal • Frequency: As desired • By: Homeowner • By: Homeowner Replace the fi rebrick if they become, cracked, broken, • Clean glass with a non-abrasive glass cleaner. Abrasive crumbly and/or if there is a 1/4 inch (6.35mm) gap between...
  • Page 19: Quick Reference Maintenance Guide

    ECO-ADV-WS22 F. Quick Reference Maintenance Guide Start the fi rst inspection after the fi rst 2 months of use, or if performance changes, and adjust your schedule accordingly. Maintenance is required for safe operation CAUTION! Allow the appliance to completely cool and must be performed to maintain your warranty.
  • Page 20: Section 4: Troubleshooting Guide

    ECO-ADV-WS22 Troubleshooting Guide With proper installation, operation, and maintenance your woodstove will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist you or a qualifi ed service person in the diagnosis of a problem and the corrective action to be taken.
  • Page 21: Section 5: Service Parts Replacement

    ECO-ADV-WS22 Service Parts Replacement B. Snap Disc Replacement A. Glass Replacement Ensure that the fi re is out and the appliance is cool to the 1. Disconnect power supply. Locate the snap disc bracket touch. assembly at the bottom left rear corner of the appliance.
  • Page 22: Baffl E Removal

    ECO-ADV-WS22 C. Baffl e Removal Baffle Boards & Blanket even with Remove all ash from the fi rebox, and extinguish all hot front tube and resting on tubes embers before disposal into a metal container. Remove the baffl e protection channel by rotating it down from the front tube.
  • Page 23: Door Handle Assembly

    ECO-ADV-WS22 D. Door Handle Assembly 1. Install washer on door handle shaft. 2. Slide door handle through door. 3. Install second washer(s) as shown in Figure 23.1. 4. Install key in groove. 5. Align groove in latch cam with key; slide latch cam over shaft 6.
  • Page 24: Tube Channel Assembly Replacement

    ECO-ADV-WS22 E. Tube Channel Assembly Replacement NOTE: Service Space Removing Tube Channel Assembly In order to replace the tube channel assembly a clear- ance of 19 inches (483mm) is required on the right side 1. Remove the baffl e protection channel, ceramic blanket of stove in order to remove the tubes with the stove in and the 2 baffl...
  • Page 25: Installer's Guide

    ECO-ADV-WS22 Installer’s Guide Getting Started A. Design and Installation Considerations C. Negative Pressure NOTICE: Check building codes prior to installation. WARNING! Risk of Asphyxiation! Negative pressure can • Installation MUST comply with local, regional, state and cause spillage of combustion fumes and soot. Fire must draft national codes and regulations.
  • Page 26: Locating Your Appliance And Chimney

    ECO-ADV-WS22 D. Locating Your Stove & Chimney • Consider the appliance location in order to avoid fl oor and ceiling attic joists and rafters. Location of the appliance and chimney will affect perfor- • Locate termination cap away from trees, adjacent mance.
  • Page 27: Rule

    ECO-ADV-WS22 F. 2-10-3 Rule These are safety requirements and are not meant to assure proper fl ue draft. Less than 10 ft. (305cm) 2 ft. (61cm) 3 ft. (91cm) 2 ft. (61cm) Minimum 10 ft. (305cm) To Nearest Roofline 3 ft. (91cm) Minimum Figure 27.1...
  • Page 28: Tools And Supplies Needed

    ECO-ADV-WS22 G. Tools And Supplies Needed Pre-Burn Check List Before beginning the installation be sure the following tools and building supplies are available: Place the appliance in a location near the fi nal installation area and follow the procedures below:...
  • Page 29: Section 7: Dimensions And Clearances

    ECO-ADV-WS22 Dimensions and Clearances A. Appliance Dimensions NOTE: Flue Collar size is 6 inch (152mm) diameter (ID) 19-1/16 in. (484mm) 26 in. (660mm) 13 in. 9-13/16 in. (330mm) (249mm) 14-13/16 in. 13-13/16 in. (376mm) (351mm) 9-9/16 in. (243mm) 34 in.
  • Page 30: Clearances To Combustibles (Ul And Ulc)

    ECO-ADV-WS22 B. Clearances to Combustibles (UL and ULC) NOTE: Clearances may only be reduced by means approved by the regulatory authority having jurisdiction BACKWALL / SIDEWALL ALCOVE SIDE VIEW 90° OFF TOP UP & OUT CEILING CLEARANCE STOVE TO CEILING...
  • Page 31: Hearth Protection Requirements

    ECO-ADV-WS22 In Canada, similar fl oor protection must be provided 18 C. Hearth Protection Requirements inches (457mm) in front and 8 inches (203mm) from the FLOOR PROTECTION: sides and rear of the appliance. *See exception. • Must be non-combustible material.
  • Page 32: Alternate Floor Protection

    ECO-ADV-WS22 D. Calculating Alternate Floor Protection Material Thermal Conductivity: k value The k value indicates the amount of heat (in BTU’s) that will fl ow in 1 hour through 1 square foot of a uniform material 1 inch thick for each degree (F) of temperature difference from one side of the material to the other.
  • Page 33: Section 8: Venting And Chimney Systems

    ECO-ADV-WS22 Venting and Chimney Systems D. Chimney Systems A. Venting Systems • The chimney connector joins the stove to the chimney. Chimney Connector: • It must be a 6 inch (152mm) minimum diameter 24 gauge It is also known as fl ue pipe or stove pipe. It must be mild steel black.
  • Page 34: Chimney Height/Rise And Run

    ECO-ADV-WS22 Listed Termination Cap E. Chimney Height / Rise and Run • This product was designed for and tested on a 6 inch Roof Brace (if required) (152mm) chimney, 14 to 16 feet (427-487cm) high, (in- cludes appliance height) measured from the base of the Storm Collar appliance.
  • Page 35: Masonry Chimney

    ECO-ADV-WS22 G. Masonry Chimney: Spark Arrestor Cap Fireclay Flue Liner Concrete Cap With Air Space Rafter Flashing 1 in. (25mm) Clearance With Firestop Ceiling Joist Eave Combustible Wall Thimble, 12 in. (305mm) Of Brick Sheathing Outside Air Rear Vent Outside Air...
  • Page 36: Masonry Chimney Liner

    ECO-ADV-WS22 H. Masonry Chimney Liner Wood Stud 2 in. For optimal performance, masonry chimneys used to vent (51mm) this appliance should be: Clearance from chimney wall Fireclay liner 5/8 in. 1. Lined with a 6 inch (152mm) stainless steel liner.
  • Page 37: Air Clearances

    ECO-ADV-WS22 I. Air Clearances • Masonry chimney clearance must meet NFPA 211 mini- mum requirement of 2 inches (51mm) to sheet metal supports and combustibles. ceiling 13.5” below ceiling to top • Minimum of 1 inch (25mm) clearance around the chim-...
  • Page 38 ECO-ADV-WS22 Solid Pack Chimney with Metal Supports as a Thimble (Cont’d) Min. Chimney Clearance to Wall Spacer and Min. Clearance Combustibles - 2 inch (51mm) 2 inch (51mm) 1 inch (25mm) Air Chimney Flue Space to Chimney Liner Section Fireclay...
  • Page 39: Section 9: Appliance Set-Up

    ECO-ADV-WS22 Appliance Set-up A. Outside Air Kit Installation 5. Floor Installation Alternative: In some instances you may not be able to install the fl ex pipe as show in A source of air (oxygen) is necessary in order for combustion to take place.
  • Page 40: Mobile Home Installation

    ECO-ADV-WS22 B. Mobile Home Installation 10. Burn wood only. Other types of fuels may generate poisonous gases (e.g., carbon monoxide). You must use an authorized Outside Air Kit Part 11. If unit burns poorly while an exhaust blower is on in OAK-ACC for installation in a mobile home.
  • Page 41: Blower Installation (Optional)

    ECO-ADV-WS22 C. Blower Installation (Optional) D. Adjusting the Blower Speed Control The blower speed control for this unit is adjusted at the factory, 1. Align holes in mounting fl ange of blower with bolt holes in and normally does not require further adjustment.
  • Page 42: Section 10: Reference Materials

    ECO-ADV-WS22 Reference Materials A. Exploded View Part number list on following page. 7057-128G • May 4, 2015...
  • Page 43: Service Parts & Accessories

    ECO-ADV-WS22 ECO-ADV-WS22 Service Parts Beginning Manufacturing Date: Mar 2010 Ending Manufacturing Date: Active B. Service Parts & Accessories IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number and serial number. All parts listed Stocked in this manual may be ordered from an authorized dealer.
  • Page 44: Door Assembly

    ECO-ADV-WS22 ECO-ADV-WS22 Service Parts Beginning Manufacturing Date: Mar 2010 Ending Manufacturing Date: Active IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for Stocked your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer.
  • Page 45: Service & Maintenance Log

    ECO-ADV-WS22 C. Service And Maintenance Log Date of Service Performed By Description of Service 7057-128G • May 4, 2015...
  • Page 46: C. Service & Maintenance Log

    ECO-ADV-WS22 C. Service And Maintenance Log (Cont’d) Date of Service Performed By Description of Service 7057-128G • May 4, 2015...
  • Page 47: Homeowner's Notes

    ECO-ADV-WS22 D. Homeowner’s Notes 7057-128G • May 4, 2015...
  • Page 48: Contact Information

    1445 North Highway Colville, WA 99114 Division of HNI INDUSTRIES Please contact your Heatilator dealer with any questions or concerns. For the number of your nearest Heatilator dealer, please visit www.heatilatorecochoice.com. NOTICE DO NOT DISCARD THIS MANUAL • Read, understand and •...

Table of Contents