Outdoor Unit (Ras-18Uah-Es3, Ras-18Uah-As3); Indoor Unit (Ras-24Ukp-Es3, Ras-18Ukp-Es3, Ras-24Ukp-As3, Ras-18Ukp-As3) - Toshiba AS-24UKHP-ES3 Service Manual

Table of Contents

Advertisement

4-3. Outdoor Unit (RAS-18UAH-ES3, RAS-18UAH-AS3)

No.
Parts name
1
Compressor
2
Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
Solenoid coil
5
(for 4-way valve)
6
Thermo sensor
7
Magnetic contactor
8
Transformer
9
Microcomputer
10
Varistor (R73, R74)
11
Fuse (F01)

4-4. Indoor Unit (RAS-24UKP-ES3, RAS-18UKP-ES3, RAS-24UKP-AS3, RAS-18UKP-AS3)

No.
Parts name
1
Fan motor (for indoor)
2
Thermo sensor (TA-sensor)
3
DC-DC transformer (T01)
4
Microcontroller
5
Heat exchanger sensor
(TC-sensor)
6
Line filter (L01)
7
Diode (DB01)
8
Capacitor (C02)
9
Fuse (F01)
10
Relay (for outdoor fan motor,
solenoid coil) (RY04)
11
Power supply IC (IC01)
12
Varistor (R21, R22)
13
Resistor (R01)
14
Louver motor
Type
Output (Rated) 1500W, 2poles, 1 phase, 220 − 240V, 50Hz
PA225X3F-4L
Winding resistance (Ω)
(at 20°C)
Output (Rated) 65W, 6poles, 1 phase, 220 – 240V, 50Hz
HF-240-42B-2
Winding resistance (Ω)
(at 20°C)
AC 450V, 2 µF
451205KQ
371456JCR
AC 370V, 45µF
AC 220 − 240V
VHV (STF)
TE / TD
10kΩ at 25°C / 50kΩ at 25°C
220 − 240V, 50Hz
CLK-26J
220 − 240V
TT-05
TMP47C840N
15G471K
470V
TSCR
T6.3A, 250V
Type
ICF-340-30-2
———
SWT-58A
TMP87CM40AN
———
SS11V-R07190
D3SBA60
KMH450VNSN120M25S 1 20µF, 450V
TSCR
AJQ1341
MA8920
15G561K
RF-5TK4R7B
MP35EA12
– 16 –
FILE NO. SVM-04007
Specifications
Red-Black
1.35
Red-Black
176.2
Specifications
DC 340V, 30W
10kΩ at 25°C
DC 390V, Secondary DC 15V, 12V, 7V
10kΩ at 25°C
19mH, AC 0.7A
4A, 600V
T6.3A, 250V
Coil DC 12V, 33mA, Rated 1A, AC 250V
5A, 900V
560V
4.7Ω, 5W
Output (Rated) 2W,10poles, 4phase,
DC 12V
White-Black
2.68
White-Black
290.5

Advertisement

Table of Contents
loading

Table of Contents