Viessmann vitodens Technical Manual page 37

Gas fired condensing boiler
Hide thumbs Also See for vitodens:
Table of Contents

Advertisement

Vitocell W 100 (type CUG 120 and 150 litres) installed below the boiler
Length
VITODENS
KW
HV
Z
HR
e
f
WW
g
h
E
k
Width
View from above
WW KW Z
E
HV TH
HR
Top view with
casing to cover
interconnecting
pipes
1.5 DHW cylinder specification
Pressure drop on secondary side,
see page 41.
Dim.
a
mm
b
mm
Dimensions
Capacity
120 litres
with casing
to cover
inter-
connecting
pipes
d
mm
875
875
e
mm
122
128
f
mm
143
149
g
mm
214
220
h
mm
339
345
k
mm
430
436
l
mm
126
191
m
mm
183
248
n
mm
276
341
Key to symbols
E
Drain
HR
Heating return
HV
Heating flow
KW
Cold water
TH
Sensor well for cylinder
temperature sensor
WW Hot water
Z
DHW circulation
200
300
2 079
2 149
1
150 litres
with casing
to cover
inter-
connecting
pipes
902
902
144
150
165
171
235
241
360
366
452
458
148
213
205
270
298
363
37

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents