4.3 Flue gas system components
Balanced flue wall bezel for interconnected air supply
(only for system size ∅ 80 mm)
250
Step in the balanced flue pipe
(e.g. in corbelled ducts)
(2 × 45º balanced flue bends)
Smallest offset (A)
100 mm for system size ∅ 80 mm (C = 222 mm)
120 mm for system size ∅ 100 mm (C = 308 mm):
4
Push two 45º balanced flue bends into each other
then into the balanced flue pipe
A
142
0.6
10
Offset
Depending on the offset (dimension A), insert one balanced flue extension
(dimension B) between both 45º bends.
System size ∅ 60 mm
Offset
Extension
Height
System size ∅ 80 mm
Offset
Extension
Height
System size ∅ 100 mm
Offset
Extension
Height
155
above 100 mm for system size ∅ 80 mm
above 120 mm for system size ∅ 100 mm:
A (mm) 150 200 250 300 350 390
B (mm)
161
232
C (mm)
249
299
A (mm) 150 200 250 300 350 390
B (mm)
122
193
C (mm)
270
330
A (mm) 200 250 300 350 390
B (mm)
170
240
C (mm)
320
360
System
Dimension
size
[mm]
∅ mm
a
b
60
60
100
80
80
125
303
373
444
501
349
399
449
489
264
384
405
500
380
430
480
547
310
380
440
410
400
505