Vitotronic 100 accessories
Vitotrol 100 (type UTA),
part no. 7170 149
H Room thermostat
H With switching output
(two-point output)
H With adjustable day program
H Standard switching times are
factory-set (individually
programmable).
H Shortest switching gap 15 minutes
Install Vitotrol 100 in the main living room
on an internal wall opposite radiators, but
not inside shelf units, niches, immediately
by a door or a heat source (e.g. direct
sunlight, fireplace, TV set, etc.).
Control unit connection:
3 core lead with a cross-section of
2
1.5 mm
(without green-yellow
conductor)
Rated voltage:
230 V~/50 Hz
Rated breaking
capacity of the
contact:
6 (1) A 250 V~
Protection:
IP 20
Permissible ambient
temperature
H during operation: 20 to +40 ºC
H during storage
and transport:
20 to +65 ºC
Setting range for set
values for standard
and reduced mode:10 to 30 ºC
Set room
temperature in
standby mode:
6 ºC
VITODENS
Vitotrol 100 (type UTD),
part no. 7179 059
H Room thermostat
H With switching output (two-point
output)
H With digital time switch
H With rotary selector for adjusting the
Permanent comfort
Permanent setback
Frost
2 permanently set programs
One individually adjustable program
and
Holiday program
H With keys for party and economy mode
Install Vitotrol 100 in the main living room
on an internal wall opposite radiators, but
not inside shelf units, niches, immediately
by a door or a heat source (e.g. direct
sunlight, fireplace, TV set, etc.).
Operation without mains power supply
(two 1.5 V round alkaline cells,
type LR6 (AA), which run for
approx.1.5 years).
Control unit connection:
2 core with a cross-section of 0.75 mm
Rated voltage:
3 V
Rated breaking
capacity of the zero volt contact
H max.:
6 (1) A 230 V~
H min.:
1 mA 5 V
Protection:
IP 20 to EN 60529,
safeguard through
design/installation
Effect:
RS type 1B to
EN 60730 1
Permissible ambient
temperature
H in use:
0 to +50 ºC
H during storage
and transport:
10 to +60 ºC
Setting range for
H Comfort
temperature:
10 to 30 ºC
H Setback
temperature:
10 to 30 ºC
H Frost protection
temperature:
6 to 10 ºC
Power backup
during battery
replacement:
10 minutes
1.2 Specification
Vitotronic 100 accessories
Cylinder temperature sensor
for Vitodens 300 from 49 kW,
part no. 7179 114
Cable length approx. 3.75 m, wired ready
to plug in
Protection:
IP 32
Permiss. ambient
temperature
H in operation:
20 to +90 ºC
H during storage
and transport:
20 to +70 ºC
KM BUS distributor,
part no. 7415 028
Including a 3.0 m long cable and LV
plug-in connector.
For the connection of 2 to 9 devices to the
Vitotronic KM BUS (e.g. Vitotrol, control
module V, etc.).
We recommend the use of the KM BUS
distributor if two or more devices are
used which are identified as KM BUS
users.
2
.