Multiword DMA timing parameters
t
Cycle time
0
t
DIOR-/DIOW-
D
t
DIOR- data access
E
t
DIOR- data hold
F
t
DIOR-/DIOW- data setup
G
t
DIOW- data hold
H
t
DMACK to DIOR-/DIOW- setup
I
t
DIOR-/DIOW- to DMACK hold
J
t
DIOR- negated pulse width
KR
t
DIOW- negated pulse width
KW
t
DIOR- to DMARQ delay
LR
t
DIOW- to DMARQ delay
LW
t
CS(1:0) valid to DIOR-/DIOW-
M
t
CS(1:0) hold
N
t
DMACK- to tri-state
Z
NOTE − t
is the minimum total cycle time, t
0
is the minimum command recovery time or command inactive time. The actual cycle time equals the sum of the actual
command active time and the actual command inactive time. The three timing requirements of t
The minimum total cycle time requirement, t
may lengthen either or both t
data. A device implementation shall support any legal host implementation.
SpinPoint P80 Product Manual Rev. 01

Table 6-23 Multiword DMA data transfer

(min)
(min)
(max)
(min)
(min)
(min)
(min)
(min)
(min)
(min)
(max)
(max)
(min)
(min)
(max)
is the minimum command active time, and t
D
, is greater than the sum of t
0
or t
to ensure that t
is equal to the value reported in the devices IDENTIFY DEVICE
D
K
0
Mode 0
Mode 1
ns
ns
480
150
215
80
150
60
5
5
100
30
20
15
0
0
20
5
50
50
215
50
120
40
40
40
50
30
15
10
20
25
and t
. This means a host implementation
D
K
Mode 2
Note
ns
120
see note
70
see note
50
5
20
10
0
5
25
see note
25
see note
35
35
25
10
25
(t
or t
, as appropriate)
K
KR
KW
, t
, t
shall be met.
0
D
K
99