Denon AVR-E400 Service Manual page 60

Integrated network av receiver
Hide thumbs Also See for AVR-E400:
Table of Contents

Advertisement

2.3. About the error code
See the table below for error codes, details of faults, and coping strategies when the firmware is updated through DPMS
(Denon Product Management Server).
Error
Details of Error code
Code
01
Log-in to DPMS failed.
Line, etc., is busy when logging into
02
DPMS.
03
Connection to DPMS failed.
Firmware file data was requested
04
but error message was received.
Firmware file data was requested
05
but it timed out.
Firmware file data was requested
06
but error message was received.
All firmware file data was requested
07
but it timed out.
Firmware file data of Main CPU was
08
requested but error message was
received.
Firmware file data of Main CPU was
09
requested but it timed out.
Error (NG) message was received
0A
when firmware of Main CPU was
downloaded.
Error (line congestion) message was
0B
received when firmware of Main
CPU was downloaded.
Error (connection failure) message
0C
was received when firmware of
Main CPU was downloaded.
0D
Received Package Version is wrong.
Connection to DPMS failed.
0E
(can not get NTP)
Main CPU failed to receive firmware
10
for rewriting sent from
DM860A (when timed out).
Display
L o g i n
f a i l e d
S e r v e r
i s
C o n n e c t i o n F a i l 0 3
C o n n e c t i o n F a i l 0 4
C o n n e c t i o n F a i l 0 5
C o n n e c t i o n F a i l 0 6
C o n n e c t i o n F a i l 0 7
C o n n e c t i o n F a i l 0 8
C o n n e c t i o n F a i l 0 9
D o w n l o a d
D o w n l o a d
D o w n l o a d
D o w n l o a d
C o n n e c t i o n F a i l 0 E
U p d a t i n g
60
Reset and update again.
Carry out the update in an
0 1
environment that has little network
load.
Carry out the update in an
environment that has little network
b u s y 0 2
load.
Check the network connection.
Carry out the update in an
environment that has little network
load.
Check the network connection.
Carry out the update in an
environment that has little network
load.
Check the network connection.
Carry out the update in an
environment that has little network
load.
Check the network connection.
Carry out the update in an
environment that has little network
load.
Check the network connection.
Carry out the update in an
environment that has little network
load.
Check the network connection.
Carry out the update in an
environment that has little network
load.
Check the network connection.
Carry out the update in an
environment that has little network
load.
Check the network connection.
Carry out the update in an
f a i l
0 A
environment that has little network
load.
Check the network connection.
Carry out the update in an
f a i l
0 B
environment that has little network
load.
Check the network connection.
Carry out the update in an
f a i l
0 C
environment that has little network
load.
Check the network connection.
Carry out the update in an
f a i l
0 D
environment that has little network
load.
Check the network connection.
Carry out the update in an
environment that has little network
load.
Turn off and on the power. Updating
f a i l
1 0
starts automatically.
Coping strategies

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Avr-x2000

Table of Contents