6.3
Floor Temperature Limits (AF mode only)
NOTE: To avoid damaging your floor, follow your floor supplier's recom-
mendations regarding floor temperature limits.
The minimum and maximum floor temperature limits are 5 °C (41 °F) and
28 °C (82 °F) by default. To modify these limits, proceed as follows:
Switch the thermostat to Standby.
Press and hold the
button.
Switch the thermostat back to On.
Release the
button when the minimum temperature
limit (FL:LO) appears.
Set the minimum temperature limit using the
Press the
button to display the maximum temperature
limit (FL:HI).
Set the maximum temperature limit using the
Press Mode/Ret to exit.

Modes of Operation

The thermostat has 3 modes of operation.
7.1

Automatic Mode

The thermostat follows the programmed schedule. To place the ther-
mostat in this mode, press Mode/Ret until
the current schedule period are also displayed.
Temporary Bypass
If you modify the setpoint temperature (by pressing the
button) when the thermostat is in automatic mode, the new tempera-
ture will be used until the beginning of the next period.
ing the bypass. You can cancel the bypass by pressing Mode/Ret.
Programmed Schedule
The schedule consists of 4 periods per day which represents a typi-
cal week day. You can program the thermostat to skip the periods
that do not apply to your situation. For example, you can skip periods
2 and 3 for the weekend.
Period
Description
Wake-up
Away from home
Return home
Sleep
The Comfort ( ) temperature is used in periods 1 and 3 and the
Economy ( ) temperature is used in periods 2 and 4. For example,
when the period changes from 1 to 2, the setpoint automatically
changes from Comfort ( ) temperature to Economy ( ) temperature.
You can have a different program for each day of the week; i.e., each
period can start at different time for each day of the week. The
thermostat has been programmed with the following schedule.
MO
TU
Period
Setting
6:00
6:00
8:30
8:30
17:00
17:00
23:00
23:00
To modify the schedule:
Press Pgm to access the programming mode. Period 1 is
selected.
Press Day to select the day to program (hold for 3 seconds to
select the entire week).
Press Hour and Min to set the start time of the selected period,
or press Clear if you want to skip the period (--:-- is displayed).
NOTE: If you wish to use only 2 periods, set periods "1 and 4" or
periods "2 and 3". Early Start will not work if you set periods
"1 and 2" or periods "3 and 4" .
Press Pgm to select another period, or press Day to select
another day. Then repeat step 3.
Press Mode/Ret to exit the programming mode.
NOTE:
If no button is pressed for 60 seconds, the thermostat will
automatically exit the programming mode.
7.2

Manual Mode

The programmed schedule is not used. The temperature must be set
manually. To place the thermostat in this mode:
Press Mode/Ret until
Set the temperature using the
TH115 A/F/AF
buttons.
buttons.
is displayed. The data of
Associated temperature setting
WE
TH
FR
SA
6:00
6:00
6:00
6:00
8:30
8:30
8:30
--:--
17:00
17:00
17:00
--:--
23:00
23:00
23:00
23:00
is displayed.
,
or
button.
7.3
In this mode, the thermostat is set to Vacation temperature. There
are two ways to place the thermostat in Vacation mode:
By pressing the
mode is activated using the
screen without flashing.
From an Aube telephone controller (CT240/CT241) or any other
remote control device equipped with a dry contact if your power
base is equipped with the ECONO input. When the contact
closes, the Vacation mode is activated and the
the screen. All buttons on the thermostat are locked. When the
contact opens, the thermostat returns to the preceding mode.
NOTE: When the Vacation mode is activated using a remote
control device, it can only be deactivated using the device.

Error Messages

7.
The measured temperature is below the thermostat's display
range. Heating is activated.
The measured temperature is above the thermostat's display
range. Heating is deactivated.
Verify the thermostat and sensor connections.
:

Technical Specifications

,
or
Power
supply: Refer to the power base's installation guide.
Display
range: 0 °C to 70 °C (32 °F to 158 °F)
flashes dur-
Ambient setpoint range (A/AF
Floor setpoint range (F
Floor limit range (AF
Display
resolution: 0.5 °C (1 °F)
Operating
Storage
temperature: -20 °C to 50 °C (-4 °F to 120 °F)
Heating cycle
Data
backup: In the event of a power failure, most settings are saved.
Only the time must be re-adjusted if the power failure lasts more than 6
hours. The thermostat will return to the mode that was active prior to the
power failure.
Warranty
Aube warrants this product, excluding battery, to be free from defects in the work-
manship or materials, under normal use and service, for a period of three (3) years
from the date of purchase by the consumer. If at any time during the warranty
period the product is determined to be defective or malfunctions, Aube shall repair
or replace it (at Aube's option).
If the product is defective,
(i)
return it, with a bill of sale or other dated proof of purchase, to the place from
which you purchased it, or
(ii)
contact Aube. Aube will make the determination whether the product should
be returned, or whether a replacement product can be sent to you.
This warranty does not cover removal or reinstallation costs. This warranty shall
not apply if it is shown by Aube that the defect or malfunction was caused by dam-
SU
age which occurred while the product was in the possession of a consumer.
Aube's sole responsibility shall be to repair or replace the product within the terms
6:00
stated above. AUBE SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF
--:--
ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES
RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WAR-
--:--
RANTY, EXPRESS OR IMPLIED, OR ANY OTHER FAILURE OF THIS PROD-
23:00
UCT. Some provinces, states or regions do not allow the exclusion or limitation of
incidental or consequential damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY AUBE MAKES ON THIS
PRODUCT. THE DURATION OF ANY IMPLIED WARRANTIES, INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE, IS HEREBY LIMITED TO THE THREE-YEAR DURATION OF THIS
WARRANTY. Some provinces, states or regions do not allow limitations on how
long an implied warranty lasts, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which
vary from province, state or region to another.

Customer Assistance

For any questions regarding product installation or operation, contact us
at:
705 Montrichard
Saint-Jean-sur-Richelieu, Quebec
J2X 5K8
Canada
Tel.: (450) 358-4600
Toll-free: 1-800-831-AUBE
Fax: (450) 358-4650
E-mail: aube.service@honeywell.com

Vacation Mode

button on the thermostat. When the Vacation
button, the
modes): 5 °C to 30 °C (40 °F - 86 °F)
mode): 5 °C to 40 °C (40 °F - 104 °F)
mode): 5 °C to 40 °C (40 °F - 104 °F)
temperature: 0 °C to 50 °C (32 °F to 120 °F)
length: Refer to the power base's installation guide
For more information on our products, visit us at:
www.aubetech.com
400-115-039-C
icon appears on the
icon flashes on
8.