TH115 A/F/AF
Owner's Guide
Thank
you
for
choosing
the
Aube TH115,
programmable thermostat that provides both energy
savings and comfort.
First Power ON
When power is applied for the first
Correct
time, the LCD displays: 0:00, MO
(Monday),
and temperature (room/
floor).
Press HOUR - MIN to set the
current time.
Press DAY to set current day.
For AF and F
models: one of the two
following messages may be displayed
if the installation is incorrect:
LO: The floor temperature is below
Incorrect
32°F (0°C), or the temperature
sensor is defective, or not con-
nected.
The heating indicator
is dis-
played and the relay is closed
(energized).
HI: The floor temperature is above
140°F (60°C), or the tempera-
ture sensor is defective.
TH115 Description
Buttons and symbols
On/Stand By Switch
a
Use this switch to put the thermostat in sleep mode
when its use is no longer required (e.g. summer).
This will not affect the clock or programming.
GFCI Warning Light and Test Button
Day & Clock Settings
Programming Mode
Mode Selection/Exit Programming
Room OR Floor Temperature
Current Mode and Setpoint
Current Program Number
Setpoint definition/Pre-defined Setpoints
Increase/Decrease Temperature
Models
A
Controls the Ambient temperature.
AF
Controls the Ambient temperature and Floor temper-
ature limit.
F
Controls the Floor temperature.
GFCI Test (GA & GB power base only)
The GFCI monitors the electrical flow for
any loss of current; if there is one, the
thermostat will cut off power to the heating
system. We recommend you test the GFCI
immediately after installing the control
module, and once a month thereafter to
ensure it is operating properly. To test:
Increase the temperature
until the
heating indicator
is displayed.
Press TEST:
• Successful: the TEST warning light is ON and
power to heating system is cut off.
• Unsucessful: the TEST warning light is OFF. Cut
power to heating system from the main power
panel and call customer service.
When successful, reset thermostat (Stand By/On) to
power the heating system.
NOTE:
If the test warning light comes ON during normal
operation, cut power to heating system from the main
power panel and have an electrician verify the installation.
Switch Selection
This thermostat is factory-set to the following values:
#
Function
UP
a
SW1
°F
Temperature format
SW2
b
Disable
Early Start
SW3
Time format
12-hour
a.
If you switch from °F to °C or vice versa, the
,
and
may need to be redefined.
b.
When using AUTO mode, the thermostat calculates the optimum start
time to obtain the desired temperature by the set time. The heating
system could be started a few hours prior to set time when required.
Switches are
located on the
rear of the control
module.
To modify any
setting, switch
UP or DN.
Temperature Setpoint
The following temperature setpoints are pre-programmed:
Default
Symbol
Description
A/AF
F
Comfort (
)
70°F
82°F
when at home
Economy (
when asleep/
64°F
68°F
)
away from home
Vacation (
during
50°F
50°F
)
prolonged absence
To modify a setpoint:
Set the desired temperature using
.
Press and Hold the
or
or
button until symbol is displayed.
Press RET to exit.
Floor temperature
limit—The floor temperature limit is
82°F. To modify this limit:
Press
and hold
Set temperature
while switching from
Press RET to exit.
ON to Stand By then
To avoid damaging your floor, we
back to On.
recommend
you
supplier's instructions.
Control Module Installation
Align the bracket tabs on the control module with the
holes located on top of the power base.
DN
Control module
°C
Enable
24-hour
setpoints
Power base
NOTE:
Keep the thermostat's air vents clean and free
from obstructions.
NOTE:
The screw cannot be removed completely.
Operating Modes
Automatic —
Executes the schedule.
Press MODE until
is displayed. The cur-
New
rent program number is displayed.
You can temporary bypass the current pro-
gram by setting a specific temperature
by pressing on a pre-defined setpoint button (
The new setpoint will be maintained until the begin-
ning of the next program.
Manual
—Maintains a constant temperature.
Press MODE until
is displayed.
Set temperature
or press (
pre-defined setpoint.
Vacation
—Maintains the Vacation setpoint
during a prolonged absence.
Press
until the icon is displayed.
follow
the
or
) .
) to use
920-115-007-00-1-A

Advertisement

loading

Summary of Contents for Aube Technologies TH115 A

  • Page 1 TH115 A/F/AF TH115 Description Switch Selection Control Module Installation Owner’s Guide Align the bracket tabs on the control module with the This thermostat is factory-set to the following values: Buttons and symbols holes located on top of the power base. On/Stand By Switch Function Thank...
  • Page 2 During this support team at: It is equipped with a proportional integral adaptive (P.I.A.) period, AUBE Technologies Inc. will repair or replace, at our Setting range (ambient): 40°F to 86°F (5°C to 30°C)
  • Page 3: Installation Instructions

    PB112 Installation Instructions For models: 120GA / 120GB / 120S / 240GA / 240GB / 240S / 240D Figure 1 Parts Power One (1) power base Two (2) screws Four (4) solderless connectors for copper wires NOTE: Special CO/ALR solderless connectors must be used for connecting aluminum conductors.

This manual is also suitable for:

Th115 afTh113 aTh116 aTh113 afTh116 afTh115 ... Show all