Replacing The Lamp Cartridge - Mitsubishi LVP-X30U User Manual

X30 data projector user manual model lvp-x30u
Table of Contents

Advertisement

R e p l a c i n g
The rated lamp life is about 1,000 hours. The rated lamp life is the average
life of the lamps produced and tested (under the test conditions of our
company) for a long term, however, it may become shorter depending on
the conditions of usage.
After the lamp has been operating for 1000 hours or longer, the STATUS
indicator on the control panel will light and the "LAMP USAGE" icon
which shows hours of total lamp usage will be displayed on the screen.
When this happens, turn off the unit and replace the lamp cartridge with a
new one. The unit will not turn on after 1100 hours. (It will go off if it is in
use.)
• DO NOT TOUCH THE LAMP immediately after it has been
used. It will be extremely hot. Allow at least one hour for the
lamp to cool before handling.
• DO NOT LOOSEN ANY SCREWS except for those men-
tioned in the instructions below. There is danger of electric
shock.
Lamp cartridge replacement procedure
1 Disconnect the power cable.
Wait at least one hour for the lamp to cool.
2 Turn the unit upside down carefully.
3 Loosen the lamp cover securing screw.
4 Remove the lamp cover.
CAUTION: Do not use a lamp cartridge other than the
Mitsubishi replacement lamp cartridge. Order this from your
dealer using the unit model number (see "Notes" below).
5 Loosen the three lamp cartridge securing screws.
(This unit has a safety switch.)
6 Hold the handle then pull the lamp cartridge upward to remove
it.
7 Install the new lamp cartridge.
8 Secure the lamp cartridge with the three screws.
9 Replace the lamp cover and secure it with the securing screw.
10 Return the unit to the normal position, connect the power cable,
and turn on the unit.
11 Reset "LAMP USAGE." (See page 25).
Notes
• When the lamp usage time reaches 1100 hours, it becomes impossible
to switch on the power and menus are not displayed. In such a case,
see "If the unit doesn't go on because lamp usage exceeds 1100
hours" on page 25.
• Obtain a replacement lamp cartridge at the store where the unit was
purchased. Please specify the following information when ordering a
replacement lamp cartridge:
– Model name : VLT-X30LP
t h e
l a m p
CAUTION
c a r t r i d g e
Step 3
Step 4
Lamp Cover
Step 5
Lamp cartridge
Step 6
Step 7
Step 8
Step 9
E – 33

Advertisement

Table of Contents
loading

This manual is also suitable for:

X30

Table of Contents