Majestic 400DVBL Installation And Operating Instructions Manual page 43

Dvbl series direct vent gas fireplace
Table of Contents

Advertisement

FUNCTIONS/OPERATION
Flame Height Control
1. Press the ON button (on the Command Center) once to turn on the main burner with maximum
flame height.
2. Press the OFF button to decrease flame height. The first two presses will decrease the flame
height to medium and low.
3. The third press on OFF will turn off the main burner. In standing pilot configuration, the pilot
will stay; in intermittent pilot configuration, the pilot will be shut off.
Turning the Fireplace Off
There are three ways to turn the fireplace off.
1. Flip the master switch to the off ("O") position
2. Press the OFF button to Medium, Low, then Off.
3. Hold the OFF button anytime for three seconds. This command of OFF will remember all last
settings before turning off. The next time the fireplace is turned on, all settings will resume.
Command Center Operations:
The following functions are available on the Command Center.
Function
Power Up
Fireplace ON
Fireplace OFF
Flame Height Up
Flame Height Down
Self Diagnostics Chart:
The Command Center has a self-diagnostic LED enabling you to troubleshoot problems and poten-
tially avoid a service call. Please refer to the charts below for indicator reference.
Fault
Conversion Cover Missing
Spark Fail
No Sensor Signal
Pilot Lockout - trial
Pilot Lockout - flame loss
Low Battery
No or Low Thermopile Power
Learning
AC Power On
74D0010
SIGNATURE COMMAND SYSTEM OPERATION INSTRUCTIONS
(continued)
Flip the master switch to the ON ("_") position to power up the system
Press the ON ▲ button on the Command Center to turn the fireplace on
Flip the master switch to the OFF ("o") position OR press the OFF ▼ button 3
times OR hold the OFF ▼ button 3 seconds
Press the ON ▲ button once to turn on the fireplace with maximum flame height
Press the OFF ▼ button to lower the flame height to Medium and Low
One RED (1 time)
Two RED (1 time)
Three RED (1 time)
One GREEN, every 2 sec. (until manual reset)
One RED-GREEN, every 2 sec. (until manual reset)
One RED, every 10s (continuously)
Two RED, every 10s (continuously)
GREEN Flashes, every 1 sec. (for 10 sec.)
GREEN solid
Operation
LED Indication
43

Advertisement

Table of Contents
loading

This manual is also suitable for:

500dvbl

Table of Contents