Majestic 400DVBL Installation And Operating Instructions Manual page 31

Dvbl series direct vent gas fireplace
Table of Contents

Advertisement

Figure 38 - Junction Box Wiring Diagram
the side walls of the fireplace. Install blowers with the
blower discharge vent facing upwards and centered on
the blower channel. See Figure 38b.
9. Attach the speed control to the fireplace control compartment floor, farthest to the
front right of the fireplace without interfering with glass latch.
10. The thermal sensor clip is located beneath the firebox floor near the center. Slide the
thermal sensor into the clip until it snaps in place. Make sure the terminals on the
thermal sensor are perpendicular to the clip. See Figure 38c.
11. Unplug the white wire from the blower and plug it into one of the thermal sensor
switch wires. Plug the other thermal sensor switch wire into the open terminal on
the blower (where the white wire was previously located). NOTE: It is important to
arrange the blower wire harness so that wires can not come in contact with blower
fan blades.
12. Plug in the blower.
13. Replace engine in reverse order of removal.
14. To test blower operation, set the variable speed blower on the LOW setting. Turn the
fireplace on high. The blower should turn on within 10 minutes.
15. If the blower does not turn on, turn the fireplace off and allow cooling. Unplug the
blower. Using a jeweler's style screwdriver, turn the white dial on the side of the
variable speed control 1/8 turn counter clockwise. See Figure 38d. This will allow
the blower motor to start at the low speed setting as the fireplace cycles on and off. Retest the blower.
Clip
Thermal
Sensor
Figure 38c - Thermal Sensor Installation
FINISHING
1. Re-install the lower access panel.
2. To use the blower, turn the knob on the speed
control clockwise. The blower should be oper-
ating at the highest speed. Continue to turn the
knob until it reaches the desired speed.
74D0010
OPTIONAL FAN/BLOWER SYSTEM
Fan Control
OFF
110/115V AC
Blower Plug
Black
White
Green
Figure 38a - Blower Wiring Diagram
FP1910
SC blower wiring diagram
8/08
Figure 38d - Location of White Dial on Speed Control
Electrical Grounding Instructions: This appliance is equipped with
a three-prong (grounding) plug for your protection against shock
hazard and should be plugged directly into a properly grounded
three prong receptacle.
Fan Light
Variable
Tan
Switch
(Hi Temp)
(N.O.)
2
1
ON
Blower
Motor
Figure 38b - Blower
Installation
Blower
Motor
Black
White
31

Advertisement

Table of Contents
loading

This manual is also suitable for:

500dvbl