If on the M110B.32SM/... model the flow rate of the
d.h.w. circuit is too high, it is possible to limit it by instal-
ling a flow limiter. The following sizes are available:
Nominal flow rate (litres/min)
10
12
14
To install the flow limiter:
1
Remove the flow switch group as explained in the
section 14.5.
2
Colour
Blue
Red
Pink
Fig. 14.4
3
4
D.h.w. flow switch, filter and flow limiter
Separate the flow switch plug 1 from the body 4
levering with a screwdriver one of the two hooks.
Insert the flow limiter 3 as shown in Fig. 14.3
Reassemble the group following the above se-
quence in reverse order.
1
4
33