To test a limiter, perform the following steps:
1.
Use an ohmmeter and set the range to R x 1.
2.
With no power applied, touch the ohmmeter leads to the following terminals. You should obtain
the following readings at the indicated temperature:
1A and 2A opens @ 1025˚F
1B and 2B closes @ 275˚F
If the readings are not within the range shown, the limiter is defective and should be replaced.
LIMITER
2A
1A
- 24 -
2B
2A
1A
1B
2B
1B