Rs696Pxeb & Rs696Pxeq - Whirlpool RS610PXE Job Aid

Vision ii drop-in range
Hide thumbs Also See for RS610PXE:
Table of Contents

Advertisement

FAILURE CODES & REFERENCE DATA
Models RS675PXEQ, RS675PXEZ,
FAULT CODE
ERROR CODE
- F0 -
All E-Codes
- F1 -
All E-Codes
- E0 -
- F2 -
- E2 -
- E0 -
- E1 -
- F3 -
- E2 -
- E3 -
- E0 -
- F5 -
- E1 -
- E2 -
- F6 -
- E0 -
- F7 -
- E0 -
NOTES:
1. The most common cause for control failure is corrosion on connectors. Therefore, disconnecting and recon-
necting wires will be necessary during test procedures.
2. All tests should be made with a VOM or a DVM having a sensitivity of 20,000 ohms per volt DC, or greater.
3. Check all connections before replacing components. Look for broken or loose wires, defective terminals, or
wires not pressed into the connector far enough.
4. Voltage checks must be made with all connectors attached to the boards.
5. Resistance checks must be made with power cord unplugged from outlet and with wiring harness or connec-
tors disconnected.
RS696PXEB & RS696PXEQ
MEANING OF
FAILURE CODE
Default F-Code
no failure.
Electronic control malfunction.
Keypad not connected.
Key held down too long or key
is shorted.
Temperature sensor opened.
Temperature sensor shorted.
Oven temperature too high.
Door is open but latch is locked.
Self-clean latch will not lock.
Self-clean latch will not unlock.
Return line not connected.
Common switch wire is
defective.
REPAIR PROCEDURE
Will only be displayed if user presses and holds Cancel key for
5-seconds and there is no pre-existing fault. Press Cancel key
again to clear display.
Replace control if the E-Code is not E3.
Check keypad connector for firm connection.
Press Cancel key. If error code returns after 60-seconds,
replace keypad.
Check sensor connection.
Measure sensor resistance (1080 ohms @ 70˚F; add 2 ohms
per degree).
If resistance is not valid, replace sensor.
If sensor resistance and connections are okay, then the oven
cavity temperature must have exceeded a safe level. Check for
relay contacts welded together on control board.
Check the latch assembly ( latch arm pivot joint, arm solenoid
connection, solenoid spring and spring washer).
Check latch solenoid.
Check for firm electrical connections.
Disconnect the two wires from the solenoid and measure the
resistance of the solenoid. A small resistance (approximately
175 ohms) is normal. If the solenoid is open (infinity) or shorted
(0 ohms), replace it.
Check the latch switch. Disconnect the switch and use a
continuity tester:
Door latched = switch closed (0 ohms).
Door unlatched = switch open (infinity).
Check door open/closed switch. Disconnect the switch wires
and use a continuity tester:
Door open = switch (1) closed circuit, switch 2 (open circuit).
Door closed = switch (1) open circuit, switch 2 (closed circuit).
If switch pulse return line is not connected, electronic control will
display F6 within 60-seconds after power-up.
Common wire (+5VDC) to latch switch and to door switch is
shorted to chassis ground or neutral.
Check connections at control and at the latch switch and door
switch.
If all connections are okay, then check the individual switches as
outlined for the F5 failure.
- 21 -

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rs696pxeRs675pxe

Table of Contents