Leveling the unit

The machine must be leveled for proper oper-
ation. The machine does not need to be in-
stalled on a base, however any unevenness in
the floor must be compensated for.
The machine can be leveled by adjusting the
screw feet.
Once leveled the discs must be turned with a
screwdriver against the machine's base plate.
M.-Nr. 05640910

Electrical connection

The electrical connections to the dryer must
be in accordance with instructions given on
the installation diagram and comply with local
regulations.
Once installed in position all detachable outer
casing parts must be attached again.
THIS APPLIANCE MUST BE GROUNDED.
Before installation, make sure that the voltage
and frequency listed on the data plate corre-
spond with the site electrical supply. The
dryers are ready for connection to a 208V,
60Hz, 20A power supply.
Make the electrical connection (L1, L2, L3,
Ground) at the terminal block. Follow the in-
structions given on the enclosed wiring diag-
ram (located on the terminal block).
WARNING
Verify that the unit is in-phase:
the ventilation motor should turn clockwise
(open the
panel to the lint filter.)
the dryer door should suck in from the
under pressure.
All removable outer housing parts must be re-
fitted after the electrical connection has been
made.
The electrical rating:
18.0 kW
27.0 kW
36.0 kW
23
T6351
T6551
T6751