Denon AVR-E300 Service Manual page 24

Integrated network av receiver`
Hide thumbs Also See for AVR-E300:
Table of Contents

Advertisement

2.3. Clearing the protection history
There are two ways to clear the protection history, as described below.
(1) Start up the set in error (protection display) mode and display the error, then press and hold down the "DIMMER"
button for 3 seconds.
FLD
P
R
T
FLD
P
R
T
FLD
N
O
(2) Initialize. (Refer to "Initializing INTEGRATED NETWORK AV RECEIVER"
b
If you want to save a backup, perform the method in 2.3.(1) above.
Warning indication by the POWER LED
If the power is turned off when a protection incident has been detected, the POWER LED (red) flashes as a warning
according to the conditions in which the protection incident occurred.
(1) ASO/DC PROTECTION : Flashes at intervals of 0.5 seconds (0.25 seconds lit, 0.25 seconds off)
(2) THERMAL (A/B) PROTECTION : Flashes at intervals of 2 seconds (1 second lit, 1 second off)
:
D
C
Press the "DIMMER " button for 3 seconds.
:
C
L
E
A
R
The above is displayed and the protection history is cleared.
P
R
O
T
E
C
T
10
24
page.)