i10
Maximum temperature This is the current temperature from
i11
DHW flow temperature The current DHW flow temperature.
i12
DHW temperature
setpoint
i14
Return temperature
i15
Outdoor temperature
i16
Pump modulation
i17
Burner modulation
i18
Fan speed
i19
Time inputs
i20
Software version
i21
Software version
i22
Heat Control Module
(HCM) number.
i23
Heat Control Module
(HCM) version number.
Table 28 Information menu listing

8.5.2 SELECTING SERVICE MENUS

1. Press and hold
and
buttons together for one second, the
ok
display will show Menu 1.
Double up or down arrows indicate that the menu can only be scrolled up
or down, an up and down arrow combination indicates position in the
menu where options can be scrolled either up or down.
2. Scroll up and down through the menus with the
on the right hand side of display.
Greenstar Si Compact
ErP
- 6 720 813 278 (2015/07)
the "Maximum safety sensor". This
sensor is mounted on the front of the
heat exchanger.
This is the temperature selected via
the Hot Water control knob on the
fascia.
The current temperature returned to
the main heat exchanger.
Optional outdoor temperature sensor
needs to be connected for this menu
to be activated.
The current pump modulation is
displayed as a percentage.
The current burner modulation is
displayed as a percentage.
The current fan speed is displayed in
Hertz. The value is up-dated in real
time.
This indicates the status of the
optional fascia mounted controls:
0 = CH off, DHW off
1 = CH off, DHW on
2 = CH on, DHW off
3 = CH on, DHW on
Firmware version of the main control
board.
Firmware version of the fascia control
display board
The last three digits of the HCM are
displayed:
586 = 25kW Combi N.G.
587 = 25kW Combi L.P.G.
588 = 30kW Combi N.G.
589 = 30kW Combi L.P.G.
For example "4"
and
buttons
eco
°C
reset
ok
°F
Eco
e
e
min
max
1.
eco
°C
reset
ok
°F
Menu 1
e
e
min
max
Test
Menu 3
Menu 2
Fig. 125 Service menu selection
FAULT FINDING AND DIAGNOSIS
1
1
0
1.
min
max
1
1
0
2.
min
max
°C
°F
°C
°F
°C
°F
°C
°F
Menu 1
2
3
bar
4
2
3
bar
4