6-11. Reset Mode

Enter reset mode by turning power On and pressing
the Program Push Button until the RST NO message
is displayed. RST NO message will not display until
after the power-up sequence is completed
(approximately 20 seconds).
RST
V
YES
A
Setup
Adjust
Rotate Adjust knob to change NO
to YES.
Setup
A
Setup
Arc Control
Press the Arc Control button to
confirm the reset.
The reset message is displayed for
2 seconds while factory program
settings are being reloaded.
During the reset mode the following
factory default programs are loaded
Program 1
Program 2
Program 3
Program 4
Program 5
Program 6
Program 7
Program 8
RST
V
NO
A
A
Adjust
Arc Control
RST
V
YES
A
A
Adjust
Arc Control
.
into the unit:
Pulse
.035 Mild Steel
90% Argon, 10% CO
2
MIG
.035 Mild Steel
75% Argon, 25% CO
2
Accu-pulse
.035 Mild Steel
90% Argon, 10% O2
Pulse
.045 Mild Steel
90% Argon, 10% CO
2
MIG
.045 Mild Steel
75% Argon, 25% CO
2
Accu-pulse
.045 Mild Steel
90% Argon, 10% O2
Pulse
.052 Mild Steel
90% Argon, 10% CO
2
MIG
.052 Mild Steel
75% Argon, 25% CO
2
.
Reset mode is not active when
Program Lock is enabled.
The reset mode allows the operator to
reload factory program settings for all
eight active programs in the unit.
.
System configuration data will be
lost during the Reset operation.
CYCL
V
PWR
A
Setup
Adjust
Arc Control
Cycl Pwr message appears on the display
when programs complete loading.
Turn power off, wait 10 seconds, and turn
power back on again to complete the reset
operation.
After Reset is complete, be sure to load
appropriate programs that contain the
correct wire size, process, and shielding gas
for the welding operation
198 993 / 803 504-B
OM-220 390 Page 25