Redefining Teach Points - Miller Electric OM-1589 Owner's Manual

Wire feeder and feeder gun
Table of Contents

Advertisement

10-2. Redefining Teach Points

Redefining IPM Teach Point
Redefining IPM is not
normally required
unless special wire or
unusual joint design
is needed.
Redefining Pulse Parameters
P r o c e s s
2 1 5
I P M
2 1 0
A p k
>4 0
A b k
6 5
P P S
5 0
T r i m
> 4 5 0
I P M
And
1
Purge
5 0
T r i m
> 4 6 0
I P M
T e a c h
O n
2 1 5
I P M
>2 1 0
A p k
4 0
A b k
3
4
2 1 0
A p k
4 0
A b k
>6 5
P P S
1 . 1
P Wm s
P r g
1
P u l s e
P r g
1
P u l s e
2
5
2 1 0
A p k
4 0
A b k
6 5
P P S
>1 . 1
P Wm s
1
IPM
IPM determines the weld metal de-
position rate.
.
Redefining IPM is not normally
required unless special wire or
unusual joint design is needed.
Use front panel parameter select
button to move > to select IPM. Use
Display Control to select teach
point value.
Press and hold Purge button while
turning Display Control to redefine
the ipm teach point. For example:
there are teach points at 215, 270,
and 325 ipm; the teach point at 270
can be adjusted to a wire feed
speed of 216 to 324 ipm.
2
Apk − Peak Amperage
3
Abk − Background Amperage
Peak and background amperage
depend on the range of the welding
power source.
4
PPS − Pulses Per Second Of
20-400
5
PWms − Pulse Width Of
1.0-5.0 Milliseconds
Use side panel controls to change
pulse parameters. See Menu Guide
for detailed programming steps.
After values are set, strike and
maintain an arc for five seconds.
Do this for each teach point.
End weld by releasing gun trigger,
not by pulling gun out of weld. Re-
peat for each custom teach point.
The taught arc length represents a
Trim (arc length) setting of 50.
Once the teach points are set, the
wire feeder adjusts parameters be-
tween teach points synergically.
Ref. S-0259 / Ref. 154 109
OM-1589 Page 33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xr-m series