6-5. Checking Or Replacing Filter Element

Tools Needed:
Torx 25
.
A complete Parts List is available at www.MillerWelds.com
1
2
3
Y Check
DC
bus
voltage
according to Section 6-4,
and be sure voltage is near
zero before touching any
parts.
Turn power Off, and disconnect
input power plug from receptacle.
Remove wrapper from unit (see
Section 6-3).
1
Filter Base
2
Filter
3
Filter Cup
Unscrew filter cup from base.
Remove cup.
Unscrew filter element from base.
Check filter element for dirt and
moisture, and replace if necessary.
Be sure that all parts are clean and
dry.
Reinstall filter element, and secure
filter cup.
Reinstall wrapper.
804 506-B