5-2. Controls Without Meters

Internal Side View
OM-1500-19 Page 22
2
3
Front Panel
6
Internal Control Panel
1
Power Control Switch
2
Jog/Purge Switch
Pressing the Jog switch allows the operator
OFF
to jog wire without energizing the contactor
1
or gas valve.
Pressing the Purge switch allows the opera-
tor to purge gas lines before welding and to
preset gas flow rate at the flowmeter.
3
Wire Speed Control
Use control to adjust wire speed within the
speed range selected by the wire speed
range switch, located on the inner control
panel.
4
CC/CV Switch
Use switch to match feeder with the output of
the power source.
5
HI/LO Speed Range Switch
Use switch to select speed range. High
range is 50 to 780 Inches per minute. Low
range is approximately half of high range.
6
Soft Start Switch
The Soft Start feature provides a smooth
start during most weld conditions. When the
trigger is pulled, the wire speed is approxi-
mately 25% of the weld wire speed, as set by
the wire speed control knob. After an arc is
established, the wire speed increases to the
weld wire speed.
When using small diameters wire, or with in-
verter power sources, it may be necessary to
turn switch off to obtain smooth starts.
After adjusting the switches, close and latch
the door before welding.