4-1. Specifications
Rated Welding
Mode
Mode
Output
Output
225 A @ 25 Volts AC,
20% Duty Cycle @ 60 Hz;
AC
15% Duty Cycle @ 50 Hz
150 A @ 25 Volts DC,
20% Duty Cycle @ 60 Hz;
DC
15% Duty Cycle @ 50 Hz
300 A @30 Volts AC,
AC
20% Duty Cycle @ 50/60 Hz
200 A @ 25 Volts DC,
DC
20% Duty Cycle @ 50/60 Hz
*While idling
Rated Welding Output
Rated Welding Output
225 A @ 25 Volts AC, 20%
Duty Cycle @ 60 Hz;
15% Duty Cycle @ 50 Hz
300 A @ 30 Volts AC,
20% Duty Cycle @ 50/60 Hz
*While idling
OM-316 Page 10
SECTION 4 − INSTALLATION
AC/DC Models
Amperage
Range
Range
Low: 30 − 150
High: 40 − 235
30 − 160
Low: 40 − 200
High: 65 − 300
30 − 200
Overall Dimensions
Height: 18-3/4 in (476 mm); Width: 12-3/4 in (323 mm); Depth: 17-1/2 in (445 mm)
Max Open-
Amperage
Circuit
Circuit
Range
Range
Voltage
Low: 30 − 150A
80 VAC
High: 40 − 235A
Low: 40 − 200
80 VAC
High: 65 − 300
Overall Dimensions
Height: 18-3/4 in (476 mm); Width: 12-3/4 in (323 mm); Depth: 17-1/2 in (445 mm)
Maximum
Amperes Input at Rated Load Output
Open-
50 Or 60 Hz, Single-Phase
Circuit
Circuit
115 V
220 V
Voltage
80 VAC
95
95
4.6*
80 VDC
80 VAC
70
70
5.4*
80 VDC
AC Models
Amperes Input at Rated Load
Output 50 Or 60 Hz, Single-Phase
115 V
220 V
230 V
95
47.5
4.6*
70
5.4*
230 V
400 V
460 V
47.5
47 5
23 7
23.7
2.3*
1.2*
67
67
39
39
34
34
3.6*
1.8*
1.3*
400 V
KW
7.2
2.3*
0.22*
67
39
11.5
3.6*
1.8*
0.22*
Weight
Weight
104 lb
104 lb
(47 kg)
134 lbs
134 lbs
(61 kg)
Weight
Weight
85 lb
(39 kg)
107 lb
(49 kg)