9. Before using the power tool, check the push lever.
Before using the power tool make sure to check that the
push lever and valve operate properly. Without nails
loaded into the power tool, connect the hose and check
the following. If the sound of operation occurs this
indicates a fault, so in such a case do not use the power
tool until it has been inspected and repaired.
○ If merely pulling the trigger causes operating sound
of driver blade movement occur, the power tool is
faulty.
○ If merely pushing the push lever against the
material to be nailed causes the sound of driver
blade movement to occur, the power tool is faulty.
Furthermore, with regard to the push lever, please
note that it must never be modifi ed or removed.
10. Use specifi ed nails only.
Never use nails other than those specifi ed and
described in these instructions.
11. Be careful when connecting the hose.
When connecting the hose and loading nails in order
not to fi re the tool by mistake, make sure of the following.
○ Do not touch the trigger.
○ Do not allow the fi ring head to contact with any
surface.
○ Keep the fi ring head down.
Strictly observe the above instructions, and always
make sure that no part of the body, hands or legs is
ever in front of the nail outlet.
12. Do not carelessly place your fi nger on the trigger.
Do not place your fi nger on the trigger except when
actually nailing. If you carry this tool or hand it to
someone while having your fi nger on the trigger, you
may inadvertently discharge a nail and thus cause an
accident.
13. Press the nail outlet fi rmly against the material to
be nailed.
When driving in nails, press the nail outlet fi rmly against
the material to be nailed. If the outlet is not applied
properly, the nails may rebound.
14. Keep hands and feet away from the fi ring head
when using.
It is very dangerous for a nail to hit the hands or feet by
mistake.
15. Beware of the tool's kickback.
Do not approach the top of the tool with your head etc.
during operation. This is dangerous because the tool
may recoil violently if the nail currently being driven in
comes into contact with a previous nail or a knot in the
wood.

SPECIFICATIONS

Type of power
Air pressure
Applicable nails
Numbers of loadable nails
Size
Weight
Nail-feeding method
Hose (inside diam.)
26
16. Take care when nailing thin boards or the corners
of wood.
When nailing thin boards, the nails may pass right
through, as may also be the case when nailing the
corners of wood due to deviation of the nails. In such
cases, always make sure that there is no one (and
nobody's hands or feet; etc.) behind the thin board or
next to the wood you are going to nail.
17. Simultaneous nailing on both sides of the same
wall is dangerous
Under no circumstances should nailing be performed
on both sides of a wall at the same time. This would be
very dangerous since the nails might pass through the
wall and thus cause injuries.
18. Do not use the power tool on scaff oldings, ladders.
The power tool shall not be used for specifi c application
for example:
when changing one driving location to another
involves the use of scaff oldings, stairs, ladders or
ladder alike constructions, e.g. roof laths,
closing boxes or crates,
fi tting transportation safety systems e.g. on
vehicles and wagons.
19. Do not disconnect the hose with your fi nger on the
trigger.
If you disconnect the hose with your fi nger on the
trigger, the next time the hose is connected, there is a
danger that the power tool will fi re a nail spontaneously,
or operate incorrectly.
20. Disconnect the hose and take out any nails left in
the magazine after use.
Disconnect tool from air before doing tool maintenance,
cleaning a jammed fastener, leaving work area, moving
tool to another location, or after use. It is very dangerous
for a nail to be fi red by mistake.
21. When removing a nail which has become stuck,
make sure to fi rst of all disconnect the hose and
release compressed air.
When removing a nail which has become stuck in the
nail outlet, fi rst of all make sure to disconnect the hose
and release compressed air inside the power tool.
Accidental fi ring of the nail could be very dangerous.
22. A female plug (air socket) should not be used in
the body.
If a female plug is installed in the body, the compressed
air sometimes can not be drawn when the hose is
disconnected so avoid this.
The tool and air supply hose must have a hose coupling
such that all pressure is removed from the tool when the
coupling joint is disconnected.
Piston reciprocating
4.9 – 8.3 bar
ref. Fig.
64 – 70 nails (2 strips)
527 mm (L) × 322 mm (H) × 125 mm (W)
3.4 kg
Spiral spring type
8 mm