Advertisement

HP Tower UPS

User Guide

Abstract
This document is for the person who installs and maintains HP UPS products. HP assumes you are qualified
in the installation of electrical equipment and trained in recognizing hazards in products with hazardous
energy levels.
Part Number: 792523-001
November 17, 2014
Edition: 1

Advertisement

Table of Contents
loading

Summary of Contents for HP T750 G4 NA/JP

  • Page 1: User Guide

    HP Tower UPS User Guide Abstract This document is for the person who installs and maintains HP UPS products. HP assumes you are qualified in the installation of electrical equipment and trained in recognizing hazards in products with hazardous energy levels.
  • Page 2: Important Safety Instructions

    • Surges withstand ability: IEEE ANSI C62.41 Category A2 (UL Listed). Regulatory Notices See HP EG regulatory notices at http://www.hp.com/support/Safety-Compliance-EnterpriseProducts. Special Symbols The following are examples of symbols used on the UPS or accessories to alert you to important information: RISK OF ELECTRIC SHOCK - Observe the warning associated with the risk of electric shock symbol.
  • Page 3: Personal Safety

    UPS to maintain an identical level of performance and safety. For questions, contact your HP representative. Important: Replace the battery module with the same type battery module, available from HP. Page 3...
  • Page 4: Table Of Contents

    6. Technical Specifications ....................16 6.1 HP T750 G4 NA/JP UPS, HP T1000 G4 NA/JP UPS, and HP T1500 G4 NA/JP UPS ......16 6.2 HP T750 G4 INTL UPS, HP T1000 G4 INTL UPS, and HP T1500 G4 INTL UPS .........17 7.
  • Page 5: Overview

    Follow all local regulations for the disposal of packing materials. End of life HP processes products at the end of their service lives in compliance with local regulations. HP works with companies in charge of collecting and eliminating our products at the end of their service lives. Product The product is made up of recyclable materials.
  • Page 6: Weights And Dimensions

    10.9 kg/24 lb. 345 x 150 x 231 mm/13.6 x 5.9 x 9.1 in. HP T1000 G4 NA/JP UPS 11.3 kg/25 lb. 345 x 150 x 231 mm/13.6 x 5.9 x 9.1 in. HP T1500 G4 NA/JP UPS 16.3 kg/36 lb.
  • Page 7 1. Overview HP T750 G4 INTL UPS HP T1000 G4 INTL UPS RS232 RS232 OUTPUT OUTPUT OUTPUT INPUT INPUT Refer to the Bottom of Refer to the Bottom of the unit for caution markings! the unit for caution markings! HP T1500 G4 INTL UPS...
  • Page 8: User Interface

    2. User Interface 2.1 Control panel The UPS has a three-button control panel. On/Off button Scroll Mute alarm 2.2 LCD window The LCD window provides useful information about the UPS, load status, events, measurements, and settings. UPS on line mode AVR (Automatic Voltage Regulation ) mode Battery mode...
  • Page 9: Ups Setting Through The Lcd

    2. User Interface 2.3 UPS setting through the LCD Tower UPS HP T750 G4 NA/JP UPS, HP T1000 G4 NA/JP UPS, HP T1500 G4 NA/JP UPS Release the scroll down button to select a menu. Output voltage Alarm Sensitivity Tower UPS HP T750 G4 INTL UPS, HP T1000 G4 INTL UPS, HP T1500 G4 INTL UPS Release the scroll down button to select a menu.
  • Page 10: Installation

    3.1 Unpacking and contents check (1) HP Tower UPS (2) Documentation (4) Two connection cables for protected equipment (HP T750 G4 INTL UPS, HP T1000 G4 INTL UPS, HP T1500 G4 INTL UPS) (5) RS-232 communication cable (6) USB communication cable Packing materials must be disposed of in compliance with all local regulations concerning waste.
  • Page 11: Communication Ports

    USB port on the computer equipment. Connect the other end of the communication cable to the USB or RS-232 communication port on the UPS. The UPS can now communicate with HP power management software. 3.4 Ground connection Page 11 792523-001 Edition 1...
  • Page 12: Operation

    4. Operation 4.1 Start-up and normal operation To start the UPS: 1. Verify that the UPS power cord is plugged in. 2. Press the button on the UPS control panel for at least two seconds. 3. Check the UPS LCD window display for active alarms. If the indicator is on, do not proceed until all alarms are cleared.
  • Page 13: Maintenance

    Note the alarm message and the UPS serial number, and then contact your service representative. 5.2 Updating the UPS firmware To update the UPS firmware, see the HP website (http://www.hp.com/go/rackandpower). 5.3 Battery module replacement Safety recommendations Warning: To prevent personal injury from hazardous energy: •...
  • Page 14: Important Battery Safety Information

    Minimize the amount of time the UPS uses battery power by matching the UPS configuration with the utility voltage (see "6.1 HP T750 G4 NA/JP UPS, HP T1000 G4 NA/JP UPS, and HP T1500 G4 NA/JP UPS", page 16 and "6.2 HP T750 G4 INTL UPS, HP T1000 G4 INTL UPS, and HP T1500 G4 INTL UPS", page 17).
  • Page 15: Spares

    Installing the new battery module Perform the removal instructions in reverse order. ● To ensure safety and high performance, only use batteries supplied by HP. ● Take care to firmly press together the two parts of the connector during remounting.
  • Page 16: Technical Specifications

    6. Technical Specifications 6.1 HP T750 G4 NA/JP UPS, HP T1000 G4 NA/JP UPS, and HP T1500 G4 NA/JP UPS Transformer Filter Charger Inverter Battery HP T750 G4 NA/JP HP T1000 G4 NA/JP HP T1500 G4 NA/ JP UPS Output Power @ 120V...
  • Page 17: Hp T750 G4 Intl Ups, Hp T1000 G4 Intl Ups, And Hp T1500 G4 Intl Ups

    6. Technical Specifications 6.2 HP T750 G4 INTL UPS, HP T1000 G4 INTL UPS, and HP T1500 G4 INTL UPS Transformer Filter Charger Inverter Battery HP T750 G4 INTL UPS HP T1000 G4 INTL UPS HP T1500 G4 INTL UPS...
  • Page 18: Support And Other Resources

    • Download and have available an Active Health System log for 7 days before the failure was detected. For more information, see the HP iLO 4 User Guide or HP Intelligent Provisioning User Guide on the HP website (http://www. hp.com/go/ilo/docs).

This manual is also suitable for:

T1000 g4 na/jpT750 g4 intlT1500 g4 na/jpT1500 g4 intl

Table of Contents