Converting from LPG to natural gas
Removing the gas restrictor
F
A
C
B
D
E
1. Pull cable from gas train A.
2. Undo union nut B and remove gas
gasket.
3. Undo 2 screws C and remove gas
train A.
4. Remove gasket D from gas train
A.
5. Remove gas restrictor E from gas-
ket D.
6. Insert gasket D in gas train A.
Gas type conversion
7. Mount gas train A with new gas gas-
ket F.
!
Please note
Tighten screws just enough
to ensure the components do
not suffer damage and will
function correctly.
8. Remove or void gas type sticker on
the top of the boiler (next to the type
plate).
63