Part 13 - Maintenance - Westinghouse WGR-076 Series Installation, Start-Up, Maintenance, Parts, Warranty

Table of Contents

Advertisement

Are terminations properly spaced from windows, doors, and other intake vents?
Have all vent terminations been installed at least one foot above exterior grade and one foot above normal snow
accumulation level?
Is vent piping properly supported?
Has vent piping been checked for leaks?
Has the exhaust vent line been pitched back to the water heater at a rate of 1/4" per foot?
Have the exhaust vent and intake pipes been properly installed to the water heater?
Install Condensate Piping / Tubing and Components
Have all condensate components included with the water heater been installed?
Is the condensate line piped with approved materials listed in this manual?
Has the condensate line been routed to a laundry tub or other drain?
Install Gas Piping
Is the gas supply line a minimum of 3/4" in diameter?
Is the gas supply line length and diameter adequate to deliver the required BTUs?
Has gas supply line pressure been measured?
Does the gas type match the type indicated on the water heater rating plate?
Has a union and shut-off valve been installed?
Relief Valve
Is the Temperature and Pressure Relief Valve properly installed and discharge line run to open drain?
Is the discharge line protected from freezing?
Wiring
Has the power and control been wired per water heater wiring diagram, this manual?
Is the electrical connection polarity within water heater requirements?
Does the power supply voltage agree with the water heater rating plate?
Is the branch circuit wire and fusing or circuit breaker of proper size?
Are electrical connections tight and properly grounded?
Start-Up, Adjust, and Test
Has the water heater been started?
If necessary, has the water heater gas valve been adjusted?
Has the installation been customized per installation location requirements?
Have all customized system parameters been tested?
Has proper water heater operation been confirmed?
Final Installation Approvals
Table 20 - Installation Checklist

Part 13 - Maintenance

In unusually dirty or dusty conditions, care must be taken to
keep water heater cabinet door in place at all times. Failure to
do so VOIDS the warranty.
Allowing the water heater to operate with a dirty combustion
chamber will hurt operation. Failure to clean the heat
exchanger as needed by the installation location could result
in water heater failure, property damage, personal injury,
or death. Such product failures ARE NOT covered under
warranty.
Signed by Technician
Hydrogen gas can build up in a hot water system served by
this water heater that has not been used for a long period of
time (generally two weeks or more). When opening a hot water
faucet in a system that has been out of use for a time, keep all
ignition sources (electrical appliances, open flame, etc.) away
from the faucet. If hydrogen is present, there will be a sound of
air escaping as water begins to flow. Allow the water to run for
a few minutes to dissipate built up hydrogen from the system.
Failure to follow these instructions can result in property
damage, personal injury, or death.
The water heater requires minimal periodic maintenance
under normal conditions. However, in unusually dirty or dusty
conditions, periodic vacuuming of the cover to maintain visibility
39
Yes
No
Yes
No
Yes
No
Yes
No
Yes
No
Date
WHL-001 Rev. 3.16.15