Metrologic MS6520 Cubit Installation And User Manual page 21

Cubit series omnidirectional bar code scanner
Hide thumbs Also See for MS6520 Cubit:
Table of Contents

Advertisement

P
M
(
ROGRAMMING
ODES
CONTINUED
6.
To enter serial program mode, send the following command
[stx]999999[etx].
7.
To exit serial program mode, send the following command [stx]999999[etx],
the scanner will respond with an [ack] and a long beep.
8.
This mode uses the current Baud Rate, Parity, Stop Bits and Data Bits
settings that are configured in the scanner. The default settings of the
scanner are 9600, Space, 2, 7 respectively. If a command is sent to the
scanner to change any of these settings, the change will NOT take effect
until after serial program mode is exited.
EXAMPLE #2: The following example will set the scanner to the factory
default settings, Disable Scanning of Code 128 bar codes, change the
beeper tone, and add a "G" as a programmable prefix.
HOST
FEATURE
COMMAND
Enter Program Mode
[stx]999999[etx]
Load Defaults
[stx]999998[etx]
Disable Code 128
[stx]100113[etx]
Alternate Tone 1
[stx]318565[etx]
Prog. Prefix #1
[stx]903500[etx]
Code Byte 0
[stx]0[etx]
Code Byte 7
[stx]7[etx]
Code Byte 1
[stx]1[etx]
Exit Program Mode
[stx]999999[etx]
The scanner will emit a long beep!
The commands sent to the scanner do not include the small superscripted
'3' that you see in front of each bar code string in the MetroSelect
THE '3' SHOULD NOT BE SENT, IT IS A CODE TYPE DESIGNATION
ONLY!
As you will note for commands requiring additional bar codes to be
scanned (such as prefixes, suffixes, timeouts, etc.), simply send the code
bytes in the same order that you would normally scan the bar codes.
)
SCANNER
ASCII REPRESENTATION
RESPONSE
02h 39h 39h 39h 39h 39h 39h 03h
[ack] or 06h
02h 39h 39h 39h 39h 39h 38h 03h
[ack] or 06h
02h 31h 30h 30h 31h 31h 33h 03h
[ack] or 06h
02h 33h 31h 38h 35h 36h 35h 03h
[ack] or 06h
02h 39h 30h 33h 35h 30h 30h 03h
[ack] or 06h
02h 30h 03h
[ack] or 06h
02h 37h 03h
[ack] or 06h
02h 31h 03h
[ack] or 06h
02h 39h 39h 39h 39h 39h 39h 03h
[ack] or 06h
®
manual.
14