A-1

TECHNICAL SPECIFICATIONS -

Product
Ordering
Name
Information Voltage
Invertec
V350-
K1728-10
PIPE
6 6 0 0 / / 5 5 0 0 H H z z
Recommended Fuse Sizes Base On The U.S. National Electrical Code And Maximum Machine Outputs
Input 50/60 Hz
Voltage
Phases
200
1
208
1
230
1
380
1
400
1
415
1
460
1
575
1
200
3
208
3
230
3
380
3
400
3
415
3
460
3
575
3
Note 1. Not rated is indicated by 4-x's in the box on the rating plate.
Note 2. When operating on these inputs, the line cord should be changed to an input conductor of 6 AWG or larger.
OUTPUT CABLES, CONNECTIONS AND LIMITATIONS
Select The output cable size based upon the following chart.
Cable sizes for Combined Length of Electrode and Work Cable (Copper) 75C rated:
DUTY CYCLE
CURRENT
100%
60%
HEIGHT
14.8 in(373 mm)
* Overall Length Including Handle, 27.8" (706mm)
OPERATING TEMPERATURE RANGE
-4°F to 104°F(-20°C to 40°C)

INSTALLATION

INVERTEC V350-PIPE
INPUT AC VOLTAGE & DC OUTPUT
Input AC
Amps/Volts/Duty Cycle
200
208-230/
380-400/
415-460/
575
1& 3 Phase
60/50 Hz
V350-PIPE INPUT CURRENT
Output
300Amps @
350Amps @
32Volts(100%)
34Volts(60%)
Not
Not
Recommended
Recommended
76
94
69
85
Not
Not
Recommended
Recommended
Not
Not
Recommended
Recommended
41
64
36
42
31
37
41
50
39
50
36
42
23
28
22
27
22
26
19
23
16
18
LENGTH UP TO 200FT.(61m)
300
350
PHYSICAL DIMENSIONS
WIDTH
13.3 in(338 mm)
TEMPERATURE RANGES
Rated DC Output
(continuous)
350A / 34V / 60%
300A / 32V /100%
Recommended
Line Cord
AWG
2
4
---
6
8
8
8
6
8
8
8
8
8
8
1/0
1/0
DEPTH*
27.8 in(706 mm)
STORAGE TEMPERATURE RANGE
-40°F to 104°F(-40°C to 40°C)
V350-PIPE
Open
Output
Range
Circuit
Voltage
AMPS
80VDC
5-425
Notes
Fuse size
Note 1
---
Note 2
125A
Note 2
125A
Note 1
---
Note 1
---
Note 2
80A
70A
50A
Note 2
80A
Note 2
80A
70A
50A
50A
50A
50A
35A
200-250 FT. (61-76m)
1/0
2/0
WEIGHT
81.5 lbs.(37.0 kg.)
A-1

Advertisement

Table of Contents
loading

Table of Contents