B-1

SAFETY PRECAUTIONS

WARNING
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts or
electrode with skin or wet clothing.
• Insulate yourself from work and
ground.
• Always wear dry insulating gloves.
------------------------------------------------------------------------
FUMES AND GASES can be danger-
ous.
• Keep your head out of fumes.
• Use ventilation or exhaust to remove
fumes from breathing zone.
------------------------------------------------------------------------
WELDING SPARKS can cause fire or
explosion.
• Keep flammable material away.
• Do not weld on closed containers.
------------------------------------------------------------------------
ARC RAYS can burn eyes and skin.
• Wear eye, ear and body
protection.
------------------------------------------------------------
See additional warning information at
front of this operator's manual.
-----------------------------------------------------------

GENERAL DESCRIPTION

The Invertec V350-PIPE offers DC Stick and
Innershield welding.

DUTY CYCLE

The V350-PIPE is rated at 350 amps, 60% duty cycle
(based on a 10 minute cycle). It is also rated at 300
amps, 100% duty cycle.

OPERATIONAL FEATURES and CONTROLS:

UPPER CONTROL PANEL

1. AMPS Meter
• Prior to STICK operation (current flow), the meter
displays preset current value (either 2 amps or +/-
3% (e.g. 3 amps on 100), whichever is greater).
• Prior to CV operation, the meter displays four dash-
es indicating non-presettable AMPS.
• During welding, this meter displays actual average
amps.
• After welding, the meter holds the actual current
value for 5 seconds. Output adjustment while in the
"hold" period results in the "prior to operation" char-
acteristics stated above. The displays blink indicat-
ing that the machine is in the "Hold" period.

OPERATION

2. VOLT METER
• Prior to CV operation (current flow), the meter dis-
plays desired preset voltage value (+/- .5V).
• Prior to STICK operation, the meter displays the
Open Circuit Voltage of the Power Source or four
dashes if the output has not been turned on.
• During welding, this meter displays actual average
volts.
• After welding, the meter holds the actual voltage
value for 5 seconds. The displays blink indicating
that the machine is in the "Hold" period.
• Output adjustment while in the "hold" period results
in the "prior to operation" characteristics stated
above.
3. OUTPUT CONTROL
• Output control is conducted via a single turn poten-
tiometer.
• Adjustment is indicated by the meters as stated
above.
4. WELD TERMINALS-REMOTE / ON
• Two status lights indicate the location of trigger con-
trol as determined by the "WELD TERMINALS"
push button.
• If trigger control is local "weld terminals on", the ON
display will be lit.
• If trigger control is remote "weld terminals remotely
controlled", the REMOTE display will be lit.
• The unit will power up in "pre-determined preferred"
trigger modes.
STICK = ON
CV = REMOTE
For all versions, these trigger modes can be over-ridden
(switched) with the WELD TERMINALS push button. When
changed, the unit will power up in the configuration it was in
when it was last powered down.
5. THERMAL
• This status light indicates when the power source has
been driven into thermal overload. If the output terminals
were "ON", the "ON" light will blink indicating that the out-
put will be turned back on once the unit cools down to an
acceptable temperature level. If the unit was operating in
the "REMOTE" mode, the trigger will need to be opened
before or after the thermal has cleared and closed after
the machine has cooled down to an acceptable tempera-
ture to establish output.
V350-PIPE
B-1