5. Contrast Adjustment (PD-179 Board)

Set the level of the VIDEO signal for driving the LCD to the speci-
fied value.
If deviated, the LCD screen image will be blackish or saturated
(whitish).
Mode
PLAY
Signal
Arbitrary
Measurement Point
Pin 9 of CN305 on FR-194
board (PANEL_VG)
External trigger: Pin 8 of
CN305 on FR-194 board
(PANEL_COM)
Measuring Instrument
Oscilloscope
Adjustment Page
A
Adjustment Address
8A
A = 2.65 ± 0.07 Vp-p
Specified Value
Adjusting method:
Order Page Address Data
1
0
01
01
2
A
02
13
3
4
F1
03
4
A
8A
5
A
8A
Processing after Completing Adjustments:
Order Page Address Data
1
A
02
00
2
4
F1
00
3
0
01
00
10 steps peak
A
Pedestal
A: Between the pedestal and 10 steps peak
Fig. 6-1-20
Procedure
Press PAUSE button.
Change the data and set the
voltage (A) to the specified
value.
Press PAUSE button.
Procedure
Press PAUSE button.
2H

6. V-COM Level Adjustment (PD-179 Board)

Set the common electrode drive signal level of LCD to the speci-
fied value.
Mode
Signal
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Adjusting method:
Order Page Address Data
1
0
01
2
A
02
3
4
F1
4
A
87
5
A
87
Processing after Completing Adjustments:
Order Page Address Data
1
A
02
2
4
F1
3
0
01
6-41
DSC-F717
PLAY
Arbitrary
Pin 8 of CN305 on FR-194
board (PANEL_COM)
Oscilloscope
A
87
A = 5.42 ± 0.05 Vp-p
Procedure