Auto White Balance 5800K Check 2; Auto White Balance 5800K Check 3 - Sony DSC-F717 Manual

Hide thumbs Also See for DSC-F717:
Table of Contents

Advertisement

DSC-F717

16. Auto White Balance 5800K Check 2

Mode
Subject
Measurement Point
Measuring Instrument
Specified Value 1
Specified Value 2
Note 1: Perform this check after "Auto White Balance 5800K
Check 1" without a break.
Note 2: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Checking method:
Order Page Address Data
1
2
3
F
94
4
F
95
Processing after Completing Adjustment:
Order Page Address Data
1
RadarW
RadarW
RadarW
CAMERA
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Displayed data of page: F, address:
94, 95
Adjusting remote commander
11 to 4D
00 to 1D, DC to FF
Procedure
"Auto White Balance 5800K
Check 1" is completed.
Remove the C14 filter on the
lens.
Check that the data specified
value 1.
Check that the data specified
value 2.
Procedure
Perform "Auto White
Balance 5800K Check 3".

17. Auto White Balance 5800K Check 3

Mode
Subject
Measurement Point
Measuring Instrument
Specified Value 1
Specified Value 2
Note 1: Perform this check after "Auto White Balance 5800K
Check 2" without a break.
Note 2: Check that the data of page: 6, address: 02 is "00".
If not, turn the power of unit OFF/ON.
Checking method:
Order Page Address Data
1
2
F
9A
3
F
9B
Processing after Completing Adjustment:
Order Page Address Data
1
6-26
RadarW
RadarW
RadarW
RadarW
RadarW
CAMERA
Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Displayed data of page: F, address
9A, 9B
Adjusting remote commander
23 to 9B
00 to 30, DA to FF
Procedure
"Auto White Balance 5800K
Check 2" is completed.
Check that the data specified
value 1.
Check that the data specified
value 2.
Procedure
Perform "Auto White
Balance 3200K Check 1".

Advertisement

Table of Contents
loading

Table of Contents