Yamaha MDX-E100 Service Manual page 14

Hide thumbs Also See for MDX-E100:
Table of Contents

Advertisement

MDX-E100
Lead-in switch position measurement mode
Load a TDYS1 disc for reproduction (high reflecting disc).
Note) Adjust the position of the lead-in switch to FF85 - FFD2.
1. Loosen 2 screws (A) fixing the mechanism switch P.C.B.
2. Retighten screws while pushing the mechanism switch P.C.B. in the arrow ( ) direction and then measure the
position of the lead-in switch again. After adjusting the position, tighten 2 screws (A) securely. (Fig.12)
Loosen 2 screws (A)
Forced rotation of loading motor
It is possible to force the loading motor to rotate by turning the jog dial when the microprocessor version (tsm13**e**)
of the test mode or EJECT appears on display. (This is used when the disc cannot be ejected.)
* To obtain the microprocessor version on display When a disc is loaded, " _ AUT _ YOBI _ " appears on display. Press
the DELETE/CANCEL key (REMOCON) in this state, and the microprocessor version will appear.
Confirmation of magnetic head installation position
• After replacing the magnetic head and the optical pick-up, be
sure to confirm their installation positions.
• To facilitate adjustment of their installation positions, bring the
optical pick-up to the center position and follow the procedure
described below.
1.Push down the up-shift arm of the magnetic head with a finger to
raise the magnetic head.
2.Looking at the unit from above, check if the magnetic head
matches with the optical pick-up objective lens.
3.Check to ensure that the magnetic head moves up and down
smoothly.
13
Lead-in switch
Mechanism SW P.C.B.
Fig.12
Note) Apply thread lock to 2 screws on the
P.C.B. after tightening them.
Magnetic head
Circumferential direction
Objective lens
Radial direction
Push down with a finger.
Magnetic head