Description of TEST modes
[ _ AUT _ YOBI _ ]
[ AUTO _ AJST _ ]
3. RESULT preparation mode
[ _ RST _ YOBI _ ]
4. RESULT mode (main adjustment)
[ _ RESULT _ _ _ ]
5. MANUAL pre-adjustment mode
[ _ MNU _ YOBI _ ]
6. MANUAL adjustment mode
[ _ MNU _ AJST _ ]
7. EEPROM setting mode
[ EEPROM _ SET ]
8. TEST-PLAY mode
[ TEST _ PLAY _ ]
[ TEST _ REC _ _ ]

1. AUTO pre-adjustment mode

1
Set the Test mode to STOP.
2
3
(REMOCON) once.
Grating adjustment is performed and
adjusted values are output.
Adjustment is completed.
4
When adjustment is OK, press the
DELETE/CANCEL button (REMOCON).
5
When adjustment is NG, press the
DELETE/CANCEL button (REMOCON).
Automatic pre-adjustment is performed. (Grating adjustment mode after this adjustment.)
Adjusted values are output by using the interface.
Automatic adjustment is performed.
Adjusted values are output by using the interface.
Continuous reproduction is performed. (Error rate on display, jump test)
Not used (Do not use this function as it is not for servicing)
Not used (Do not use this function as it is not for servicing)
Not used (Do not use this function as it is not for servicing)
Not used (Do not use this function as it is not for servicing)
Various factors of the digital servo function are changed manually.
Each servo function is turned on independently.
The voltage is measured at the temperature detect terminal and the standard value is set.
Continuous reproduction from the specified address is performed.
C1 error rate is measured and ADIP error rate is measured.
Continuous recording from the specified address is performed.
The position where the INNER switch is turned ON is measured.
To TEMP setting (of EEPROM setting)
To CONTROL setting (of EEPROM setting)
Laser power setting (record/reproduction power) is performed.
Low reflecting disc (MMD-318) only
No disc is loaded.
Auto pre-adjustment menu
Auto pre-adjustment is started after sliding to the innermost
track.
" *** " changes in the following order during automatic
adjustment.
HAo -> RFg -> SAg -> SBg -> PTG -> PCH -> GTG -> GCH ->
RCG -> SEG -> RFG -> SAG -> HAO -> HEO -> TCO -> LAO
Proceed to Step 4 when adjustment is OK.
Proceed to Step 5 when adjustment is NG.
The display returns to the AUTO pre-adjustment menu.
There is an abnormality at the adjusted point such as HAo.
Refer to "Troubleshooting". (page 20)