Samsung AE090JXYDEH User Manual page 38

Hide thumbs Also See for AE090JXYDEH:
Table of Contents

Advertisement

• Code 30✴✴ : User's options for domestic hot water(DHW) tank heating
3011 : Application of DHW tank in user's system
302✴ : Heat pump variables for tank temp. control and combination with booster heater
303✴ : Booster heater variables for combination with heat pump
304✴ : Periodical disinfection heating of water tank
305✴ : Off timer for power DHW mode by Forced DHW of wired remote controller
3061 : Combination of external field solar panel for with heat pump for DHW heating
307✴ : Default direction of the DHW valve or Zone #1, #2 valve
When the 3way valve is applied to DHW Valve terminal block instead of 2way valve, default direction is Space
Heating (Room)
Main Menu &
Sub Menu Function
Code
DHW Code
Domestic Hot Water Tank
30✴✴
Heat Pump
Booster Heater
Disinfection
Forced DHW operation
Solar Panel/DHW Thermostat
Direction of DHW valve
EHS_MONO- KIT_IB_05402A-00_EN.indd 37
Field Setting Value
Description
Sub Code
Application
✴✴11
Max Temp
✴✴21
Stop
✴✴22
Start
✴✴23
Min. Space heating
✴✴24
operation time
Max. DHW operation time
✴✴25
Max. Space heating
✴✴26
operation time
Application
✴✴31
Delay Time
✴✴32
Overshoot
✴✴33
Compensation Temp
✴✴34
Application
✴✴41
Interval
✴✴42
Start Time
✴✴43
Target Temp
✴✴44
Duration
✴✴45
Timer OFF Function
✴✴51
Timer Duration
✴✴52
H/P Combination
✴✴61
DHW Tank
✴✴71
ENGLISH-37
Default
Min
Max
Step
0(No)
0
1(Yes)
-
50
45
50
1
2
2
10
1
5
5
20
1
5
1
20
1
30
5
95
5
3
0.5
10
0.5
1(On)
0(Off)
1
-
20
20
95
5
0
0
4
1
10
0
20
1
1(On)
0(Off)
1
-
Fri(5)
Sun(0)
All(7)
1
23
0
23
1
70
40
70
5
10
5
60
5
0(Off)
0
1(On)
-
6
3
30
1
0
0
2
-
0(Room)
0
1(Tank)
-
2015-03-16 오전 11:51:53
Unit
-
˚C
˚C
˚C
min
min
hour
-
min
˚C
˚C
-
day
o'clock
˚C
min
-
(x10)
min
-
-

Hide quick links:

Advertisement

Table of Contents
loading