4) Volume fixed [VOLUME FIXED]
Option
"VARIABLE", "FIXED", "ACCTRL" or "AC/RCCTRL" (loop enabled)
Default
"VARIABLE"
Function
VARIABLE
FIXED
AC CTRL
AC/RC CTRL
Exception
In the adjustment process, the volume can be set to any level regardless of this setting.
Disabled key when
VOLUME UP/DOWN
setting to FIXED
MUTE
* Main units's key is enabled for operating menu.
Remarks
[MAXIMUM VOLUME] has priority to [VOLUME FIXED]
* When setting to FIXED, Maximum volume is fixed.
The volume of the headphones is fixed.
When setting to "FIXED", the volume is not displayed in operating Disabled key.
In menu operation, the main unit's keys (Vol (+/-)) are enabled.
In setting to FIXED, ONVOL of On TIMER is not selected (Eliminate Item).
In setting to AC/RC CTRL, ONVOL of On TIMER i is not selected (Eliminate Item)
5) Volume fixed level [VOLUME FIXED LEVEL]
Option
0~60 (loop disabled)
Default
20
Function
The volume is fixed to the adjusted value (the main unit's speaker only).
Exception
In the adjustment process, the volume can be set to any level regardless of this setting.
Remarks
When [VOLUME FIXED] is set to "VARIABLE", the setting cannot be changed.
VOLUME can be abbreviated to VOL.
6) Remote control operation [RC BUTTON]
Option
"RESPOND", "NORESPOND" or "LIMITED" (loop enabled)
Default
"RESPOND"
Function
The operation of the remote control's keys is set.
RESPOND
NO RESPOND
LIMITED
Exception
All the keys are enabled regardless of this setting while entering the adjustment process mode, inspection mode or
Public Mode setting screen.
Remarks
The enable keys when setting to "LIMITED" are depended on Model.
7) Main Unit Operation [PANEL BUTTON]
Option
"RESPOND" or "NO RESPOND" (loop enabled)
Default
"RESPOND"
Function
RESPOND
NO RESPOND
Exception
The start operation in the adjustment process mode, inspection mode are enabled regardless of this setting.
All the keys are enabled regardless of this setting while entering the adjustment process mode, inspection mode or
Public Mode setting screen.
For the models with the MENU key on the main unit, menu operation is possible regardless of the setting during the
initial setting when the power is turned on for the first time.
: The volume is not fixed.
: The volume is fixed to the value adjusted in the volume fixed level.
: The unit starts at the volume specified in the volume fixed level, when power is turned on in the
case of the AC-ON only.
: The unit starts at the volume specified in the volume fixed level, when power is turned on in
any case.
(AC→ON, remote control→ON, main utit's key→ON)
[both remote control and main unit]
: The remote control's keys in the normal state are enabled.
: The remote control's keys in the normal state are disabled.
The POWER key (RECEPTION/STANDBY key) is also disabled.
: Only a part of keys (CHANNEL, etc.) is enabled and other keys are disabled.
: The main unit's keys are enabled.
: The main unit's keys are disabled excluding the POWER key (RECEPTION/STANDBY key).
5 – 32