Start Mode; Input Fixed; Speaker On/Off Selection; Remote Control Path Through - Sharp LC-60LE740E Service Manual

Hide thumbs Also See for LC-60LE740E:
Table of Contents

Advertisement

LC-60/70LE740E/RU,741E/S,743E,60LE840E/RU,841E/S,843E,80LE645E/RU,646E/S,648E
11) Start mode [INPUT MODE START]
Option
"NORMAL" or "Input source 1 (input selection or channel)" ... (loop enabled)
Default
"NORMAL"
Function
Which kinds of input source or channel is decided when the power turning on.
NORMAL
Remarks
When setting to not Normal, ON TIMER (Watching reservation) has priority.
When setting to "NORMAL", [INPUT MODE FIXED] is set to "VARIABLE" and [INPUT MODE FIXED] is prohibited to
select. (selection impossible.)
Example of option: "NORMAL", "TVD (002TV)", "INPUT1", "INPUT2", "INPUT3", "HDMI1", "HDMI2", "HDMI3", "HDMI4".
12) Input fixed [INPUT MODE FIXED]
Option
"VARIABLE", "FIXED", "ACCTRL" or "AC/RCCTRL" (loop enabled)
Default
VARIABLE
Function
VARIABLE
FIXED
AC CTRL
AC/RC CTRL
Disabled key when
CHANNEL (+/-), DIRECT CHANNEL buttons, FLASHBACK, INPUT SELECT, TV/VIDEO, AUTO PRESET,
setting to "FIXED"
MANUAL MEMORY, i.LINK, DIRECTINPUTSELECT, ATV, DTV, EPG, RADIO etc...
Remarks
If [INPUT MODE START] is Normal, this function cannot be set.
Set to "VARIABLE" automatically.
When setting to "FIXED",
The item related to the channel setting and input selection in Menu are not displayed.
ON TIMER (Watching reservation) is not active.
* These items does not exist according to the model.
13) Speaker ON/OFF selection [LOUD SPEAKER]
Option
"ON" or "OFF" (loop enabled)
Default
ON
Function
ON
OFF
Remarks
When the VOL (+/-) key is pressed, the mute icon is displayed for 4 seconds.
For the MUTE key and sound-related keys, caution is displayed.
For the headphones, normal operation is possible.
14) Remote control path through [RC PATH THROUGH]
Option
"OFF", "ON: TVRCE" or "ON: TVRCD" (loop enabled)
Default
OFF
Function
The item decide whether the signal received by the remote control's light-receiving section is output to the blankpin (9pin)
of RS232C.
OFF
ON: TVRCE
ON: TVRCD
Exception
In the case of "ON: TV RCD", the start operation in the adjustment process mode, inspection mod are enabled
In the case of "ON: TV RCD", all the keys are enabled regardless of this setting while entering the adjustment process
Remarks
* Remote control path through does not exist according to the model.
15) 232C power ON control [232C POWON]
Option
"ENABLE" or "DISABLE" (loop enabled)
Default
DISABLE
Function
The item decide whether Power ON by the 232C command is enabled/disabled in the standby state.
The same function as 232C command "RSPW".
ENABLE
DISABLE
: The content of the last memory is followed.
: If [INPUT MODE START] is set to Normal, input mode is not fixed.
: When "INPUT MODESTART" is active, it is impossible to switch to another channel or input
source.
: When "INPUT MODESTART" is active the unit starts at the input mode which is selected when
power is turned on in the case of the AC-ON only.
: When "INPUT MODESTART" is active the unit starts at the input mode which is selected
when power is turned on in any case.
(AC→ON, remote control→ON, main utit's key→ON)
: The sound from the speakers is output.
: The sound from the speakers is not output even if the headphones are not used.
: This function is not active.
: This function is active, and remote control is active, too.
: This function is active, but remote control is not active.
regardless of this setting.
mode, inspection mode or Public mode setting screen.
: POWR0001 is always enabled.
: Start-up may be impossible at POWR0001.
(If the 232C command reception module is set to OFF, the command is invalid.)
5 – 12

Advertisement

Table of Contents
loading

Table of Contents