2-2. Major Component Specifications

Model
SA– 128S5
Controller
PCB
Part No.
Controls
Control circuit fuse
Remote Control Unit
Compressor
Type
Compressor model
Source
Nominal output
Compressor oil ... Amount
Coil resistance (Ambient temp. 25°C)
Safety devices
Run capacitor
Fan & Fan Motor
Type
Dia. / Depth
Fan motor model ... Q'ty
Source
No. of poles ... rpm (230 V, High)
Nominal output
Coil resistance (Ambient temp. 20°C)
Safety devices
Run capacitor
Heat Exch. Coil
Coil
Rows
Fin pitch
Face area
External Finish
Type
Overload relay
Operating temp.
Open
Close
Operating amp.(Ambient temp. 25°C)
Type
Operating temp.
Open
Close
220–240V Single phase 50Hz
W
cc
SUNISO 4GSD-T ... 550
°C
°C
µF
VAC
Indoor
Centrifugal
mm
ø210 / D96
YSK70-4A-661 ... 1
220–240V Single phase 50Hz
W
YEL-ORG(PNK) : 62.7
°C
°C
µF
VAC
Evaporator
2
mm
1.4
2
m
0.095
Acrylic baked-on enamel finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
3
Rotary (Hermetic)
C-R110H5H 80619445
1,100
C–R : 1.962
C–S : 5.38
External protector
MRA98619-9200
150±5
69±11
Trip in 6 to 16 sec. at 22.5A
25.0
400
ø320 / D —
4 ... 1,010
20
WHT-BRN : 60.0
WHT-YEL : 19.6
Internal protector
130±5
Automatic reclosing
3.5
440
Condenser
Outdoor
Propeller
3
1.6
0.155