Cirrus Design
SR22
Maximum airflow
to defroster.
Shared airflow to the
defroster, cabin floor,
and panel outlets.
Maximum airflow to
the rear seat foot warmer
diffusers and the front
seat kickplate outlets.
Maximum airflow
to the panel and
armrest air gaspers.
Air conditioning mode.
AC ON illuminated.
NOTE: Illustration depicts settings for Emergency Procedures
Smoke and Fume Elimination.
If source of smoke and fume is firewall forward, turn
Airflow Selector OFF.
P/N 13772-002
P/N 13772-002
Reissue A
Rotating the selector controls the volume of airflow
allowed into the cabin distribution system through
use of an electro-mechanical linkage to a butterfly
(hot air) valve in the mixing chamber on the forward
firewall. When the airflow selector fan speed is
moved to the 1, 2, or 3 position the electro-mechanical
linkage actuates the hot air valve to the full open
position and the 3-speed blower fan is turned on.
VENTS
Rotating the selector simultaneously
opens and closes the hot and fresh air
butterfly valves, permitting conditioned
(mixed) air to enter distribution system.
Figure 7-16
Environmental System Operation
Section 7
Systems Description
AIRFLOW
Maximum air
conditioning
(recirculation)
mode. AC ON
illuminated.
TEMPERATURE
SR20_FM09_3362
7-67
7-67