3.3 Programming the V-SIPGW16 Card—Shelf
Property
Common settings for all of the V-SIPGW cards installed in the virtual shelf can be programmed.

Accessing Shelf Properties

1.
Under Configuration, click Slot.
2.
Move the mouse pointer over the small PBX image for virtual slots.
3.
Click Select Shelf.
4.
Move the mouse pointer over the V-SIPGW16 card.
5.
Click Shelf Property.

Programming Shelf Property

Icon Description
In this section, the following icons show the different parameter type.
Icon
Description for Parameter Type
Manual programming is compulsory under certain conditions.
Not marked
Manual programming is optional.

3.3.1 Main

SIP Client Port Number
Specifies the port number of the PBX used for communications with the SIP server.
Default
35060
Value Range
1–65535
NAT Traversal
Specifies the NAT traversal method.
STUN: A STUN Server, used alongside the SIP Server, finds out the global IP address of the router with
NAT enabled.
Fixed IP Address: The global IP address of the router with NAT enabled is fixed.
Note
Manual programming is optional except when programming is required depending on the network
conditions.
Default
Off
Document Version 2011-10
Programming Manual for Virtual SIP CO Line Card