LOCAL CODES

Install and use heater with care. Follow all local
codes. In the absence of local codes, use the lat-
est edition of The National Fuel Gas Code, ANSI
Z223.1/NFPA 54*. Firebox must be electrically
grounded in accordance with the National Electri-
cal Code, ANSI/NFPA70 (latest edition).
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269

PRODUCT FEATURES

OPERATION
This firebox is designed for use with approved ANSI
Z21.11.2 decorative type unvented room heaters.
(Physical size limitations apply. Refer to minimum
firebox requirements supplied with log heater.) It
requires no outside venting or chimney making in-
stallation easy and inexpensive. When used without
the blower, the firebox requires no electricity mak-
ing it ideal for emergency backup heat.
REFRACTORY BRICk LINER
Your firebox may feature a concrete refractory
brick liner. As with all concrete liners, this liner
may develop slight cracks when exposed to heat.
These cracks will not affect the performance of
the fireplace or vent-free gas logs.
OUTSIDE AIR kIT ACCESSORY
The optional AK4 air kit provides additional out-
door air to improve burner efficiency and reduce
build-up of condensation in the living space. Fol-
low the instructions included with the air kit.
4

LOCATINg FIREBOX

PLANNING
Plan where you will install the firebox. This will
save time and money later when you install the fire-
box. Before installation, consider the following:
1. Where the firebox will be located. Allow for
wall and ceiling clearances (see Installation
Clearances, page 10).
2. Everything needed to complete installation.
3. These models CANNOT be installed in a
bedroom unless the maximum Btu rating
of the installed vent-free log set is less than
10,000 Btu/hr.
4. Proper air for combustion and ventilation
(page 7).