Troubleshooting
Malfunction
Cause
■ Fuse faulty, not switched
Sensor without power
'ON', break in wiring
■ Short circuit
■ Twilight control set to night-
Sensor will not switch 'ON'
time mode during daytime
operation
■ Bulb faulty
■ Power switch 'OFF'
■ Fuse faulty
■ Detection zone not properly
targeted
■ Continuous movement in the
Sensor will not switch 'OFF'
detection zone
■ Light being operated in the
detection zone causing sen-
sor to respond as a result of
change in temperature
■ Light being operated is in
the manual override mode
(LED 'ON')
■ Lamp being operated in
Sensor keeps switching
'ON'/'OFF'
the detection zone
■ Animals moving in the
detection zone
■ Wind is moving trees and
Sensor responds when it
should not
bushes in the detection zone
■ Cars in the street are being
detected
■ Sunlight is falling onto
the lens
■ Sudden temperature
changes due to weather
(wind, rain, snow) or air
expelled from fans, open
windows
■ Dazzle guard active
■ Differing ambient
Change in sensor's reach
temperatures
■ Load connected is too high
LED flashing rapidly
(approx. 5 x per second)
Remedy
■ New fuse, turn 'ON' power
switch, check wiring with
voltage tester
■ Check connections
■ Reset
■ Change bulb
■ Switch 'ON'
■ New fuse, check connection
if necessary
■ Re-adjust
■ Check zone, adjusting if
necessary, or shroud
■ Change zone, or shroud
■ Deactivate manual override
■ Change zone, shroud or
increase distance
■ Change zone, or shroud
■ Change detection zone
■ Change detection zone
■ Mount sensor in a sheltered
place or change detection
zone
■ Change detection zone,
change site of installation
■ Operate manually at push-
button/switch
■ No movement detected
within the selected stay-'ON'
time + 60 sec. (dazzle guard)
■ Use shrouds to define
detection zone precisely
■ Reduce load or use
contactor
18
Technical specifications
IS 3360/
IS 3180
IS 3360 ECO
Dimensions:
(L x W x H) 95 x 95 x 65 mm
Output:
Incandescent lamps, 2000 W max. at 230 V AC
Fluorescent tube, 1000 W max.
at cos ϕ = 0.5, inductive load at 230 V AC
8 x 58 W max., C ≤ 176 μF
at 230 V AC
Power supply:
230 – 240 V, 50 Hz (2.5 mm
Angle of coverage: 180° with 90°
360° with 180°
angle of aperture
angle of aperture
Reaches:
Basic setting 1:
IS 3360
8 – 20 m max.
20 m max.
tangentially;
tangentially;
temperature-
temperature-
stabilised
stabilised
Basic setting 2:
IS 3360 Eco
4 – 8 m max.;
10 m max.,
temperature-
temperature-
stabilised)
stabilised
+ precision adjust-
+ precision
ment by re-pos-
adjustment using
itioning the lens
shrouds
and using shrouds
Detection levels:
7
11
Switching zones:
448
1416
Time setting:
5 sec. – 15 min. + pulse mode (approx. 2 sec.)
Twilight setting:
2 – 2000 lux + teach mode
Manual override:
selectable (4 hrs.)
IP rating:
IP 54
Protection class:
II
Temperature
range:
- 20 °C to + 50 °C
*
1)
Fluorescent lamps, low-energy lamps, LED lights with electronic ballast
(total capacity of all ballasts connected below the level stated).
Declaration of Conformity
This product complies with
- Low-Voltage Directive 2006/95/EC
- EMC Directive 2004/108/EC
IS 345
IS 345 MX
*1)
2
max.)
180° with 45°
180° with 45°
angle of aperture
angle of aperture
20 x 4 m max.
max. of 30 x 4 m
(tangentially),
(radially) mounted
12 x 4 m max.
at a height of
(radially);
12 m;
temperature-
temperature-
stabilised
stabilised
Precision adjust-
ment by re-pos-
itioning the lens
and using shrouds
5
5
280
120
19

Advertisement

loading

This manual is also suitable for:

Is 3360 ecoIs 345 mx highbayIs 3360Is 345